You are viewing an archived code
The provisions of ICC/ANSI A117.1 are adopted by reference as set forth in Section 18-11-1101.3 and shall apply with the following modifications.
1. 302.1 (Floor or Ground Surfaces). Add exceptions to read:
“1. This section shall not apply within an area of sport activity.”
“2. Animal containment areas designed and constructed for public use shall not be required to comply with this section or with Section 303.”
2. 404.2.9 (Door Opening Force). Add item 3 to read: “3. Exterior hinged door: 8.5 pounds (37 N).”
3. 502.2 (Parking spaces). Revise to read: “Vehicle parking spaces shall be 132 inches (3350 mm) wide minimum.
Exception: Parking spaces serving buildings or facilities with 19 or fewer Type B units may be 96 inches (2438 mm) wide minimum.”
4. 803 (Dressing, fitting and locker rooms). Add the following: “803.4 Mirror. If mirrors are provided in dressing rooms of the same use, accessible dressing rooms shall be provided with a full-length mirror measuring 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum mounted in a position to afford a view to a person on the bench and to a person in a standing position.”
5. 904.3.1 and 904.3.2 (Sales and service counters, approach). Change to read: “904.3.1 Parallel Approach. A portion of the counter surface 36 inches (915mm) minimum in length and 34 inches (865) maximum in height above the floor shall be provided. Where the counter surface is less than 36 inches (915 mm) in length, the entire counter surface shall be 34 inches (865 mm) maximum in height above the floor. A clear floor space complying with Section 305, positioned for a parallel approach adjacent to the accessible counter, shall be provided.
904.3.2 Forward Approach. A portion of the counter surface 30 inches (760 mm) minimum in length and 34 inches (865 mm) maximum in height above the floor shall be provided. A clear floor space complying with Section 305, positioned for a forward approach adjacent to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter.”
6. 1003.11.7 (Water closets – Type A Dwelling Units). Add the following: “1003.11.7.6 Toilet paper dispensers. Toilet paper dispensers shall comply with Section 604.7.”
7. 1003.12.6.4 (Ranges and cooktops – Type A units). Add the following sentence: “The clear floor space shall be centered on the range or cooktop.”
8. 1004.12.2.5 (Refrigerator/Freezer – Type B Units). Add the following sentence: “The centerline of the clear floor space shall align with the centerline of the dedicated space for the refrigerator/freezer.”
(Amend Coun. J. 7-26-06, p. 81373, § 1)