15-12-190  Test assemblies.
   (a)   Test assemblies shall be truly representative as to material, workmanship of the construction and details, including installation, glass size, method of closing, hardware, trim and finish.
   (b)   The fire-resistive rating derived from the test shall be assumed to apply to all like assemblies smaller in dimension and area than the test specimen and to larger sizes not exceeding the area of the test specimen by more than 25 percent.
(Prior code §  65-6.3)