Unobstructed walk areas not less than six feet wide shall be provided to extend entirely around the pool. The walk area shall be constructed of impervious material, and the surfaces shall be such as to be smooth and easily cleaned and of nonslip construction. The slope of the walks shall have a pitch of at least one-fourth inch to the foot, designed so as to prevent back drainage from entering the pool. Walk drains shall be provided for each 100 square feet of walk area. Drain pipe lines shall be at least three inches in diameter; drain openings shall have an open air of at least four times the cross sectional area of the drain pipe. The walk drain system shall have indirect connection to the sewer in accordance with Chapter 18-29 of this Code. The walk drains shall not be connected to the recirculation system piping. The drainage system shall be constructed in conformance with Chapter 18-29 of this Code. Reference is also made to Section 13-96-770(c).
(Prior code § 61-18.8; Amend Coun. J. 11-9-16, p. 36266, § 20)