13-96-550  Protection of openings.
   (a)   When the exterior wall of a filling station is less than five feet from a property line or adjacent structure, no opening shall be placed in such wall.
   (b)   All openings in walls located less than 12 feet from an interior lot line or from any adjacent structure shall be protected with fire windows or fire doors complying with the requirements of Chapter 15-12.
(Prior code § 61-15.4)
13-96-560  Grading and sills.
   Unless driveways are graded to prevent gasoline spills or overflows from flowing into or under buildings, door sills shall be raised above the outside ground level.
(Prior code § 61-15.5)
ARTICLE XV.  GREENHOUSES (13-96-570 et seq.)
13-96-570  General requirements.
   Every greenhouse hereafter erected shall comply with all applicable provisions of this Code and with the special provisions of Sections 13-96-580 to 13-96-600, inclusive.
(Prior code § 61-16)
13-96-580  Accessory structures.
   A greenhouse on the same lot with a building of another occupancy and not exceeding 400 square feet in area nor 15 feet in height shall be considered an accessory structure. Such structures shall be permitted within the fire limits in accordance with Section 13-116-130(j).
(Prior code § 61-16.1)