922.14 GREASE TRAP MAINTENANCE REQUIREMENTS.
   (a)   New and existing grease traps shall be properly maintained in efficient operating condition by thoroughly cleaning and removing accumulated grease on a monthly basis, or more frequently as required by the City of Aurora.
   (b)   New and existing grease traps shall be maintained free of all food residues and any FOG waste removed during the cleaning and scraping process. Materials removed from grease traps shall be disposed of properly and NEVER discharged into the municipal sewage collection system.
   (c)   New and existing grease traps shall be inspected periodically to check for leaking seams and pipes, and for effective operation of the baffles and flow-regulating device. Grease traps and their baffles shall be maintained free of all caked-on FOG and waste. Removable baffles shall be removed and cleaned during the cleaning and maintenance process.
   (d)   Food waste disposal units shall not be connected to or discharged into any grease trap.
   (e)   Reporting and record keeping requirements related to grease trap maintenance are detailed in Sections 922.17 through 922.20 . (Ord. 2010-184. Passed 2-14-11.)