5.4.7.   Maximum Illumination Levels
Exterior lighting shall be designed and located such that the maximum illumination measured in footcandles at ground level at any lot line shall not exceed the standards in Table 5.4.7: Maximum Illumination Levels.
TABLE 5.4.7: MAXIMUM ILLUMINATION LEVELS
Type of Abutting Use or Zoning District [1]
Maximum Illumination Level at the Lot Line (Footcandles) [2]
TABLE 5.4.7: MAXIMUM ILLUMINATION LEVELS
Type of Abutting Use or Zoning District [1]
Maximum Illumination Level at the Lot Line (Footcandles) [2]
Single-family residential or duplex use or land zoned for single-family development
0.5
Multi-family or mixed-use development or land zoned for multi-family or mixed-use development
0.5
Mixed-use development or land zoned for mixed-use development
1.5
Institutional use [3]
2.0
Commercial or industrial use or land zoned for uses other than residential
2.5
Public or private street right-of-way
5.0
NOTES:
[1] These are the kinds of uses or zoning districts that abut the development. The maximum allowable illumination along any lot line shared with a single-family residential use is 1.0 footcandles, regardless of the type of use deploying the exterior lighting.
[2] In cases where a single development occupies multiple lots, the lot line shall be the lot line(s) around the perimeter of the project.
[3] Use types are organized by use classification in Table 4.2.3, Principal Use Table.