§ 179.015 WATER TREATMENT EQUIPMENT.
   A private pool shall be equipped with a recirculating system which shall be capable of filtering and recirculating the entire volume content of the pool during a 12-hour period. The rate of application of pool water on the filters shall not be greater than three gallons per minute per square foot of filter area. The Health Department may approve other rates of recirculation or rates of application of water on the filters.
(Prior Code, § 33-30) Penalty, see § 10.999