(a) Only metal support, galvanized construction, or equal thereto, shall be allowed.
(b) Only a concrete base or caissons, depending on soil conditions, shall be employed in line with grade.
(c) The structure shall be designed to withstand wind force of up to one hundred (100) miles per hour in a manner conforming with good engineering practices.
(d) Any driving motor shall be limited to 110V maximum power design and be encased in protective guards.
(e) All underground electrical wiring must be encased in rigid conduit with eighteen (18) inch cover.
(f) All electrical wiring must meet the approval of the electrical inspector.
(g) The antenna must be bonded to an eight (8) foot grounding rod.
(h) If guy lines are to be used, they must be confined within the fenced area as outlined in Section 1369.08.