TABLE 6.3-4.B: EXCEPTIONS TO THE C-1, C-2, C-3, OCR-1, & OCR-2 DIMENSIONAL STANDARDS
Use
Exceptions to the ’s Dimensional Standards
Use
Exceptions to the ’s Dimensional Standards
C-1
Golf Course (P)
(min.) = 30
(max.) = 10%
Cemetery (P)
(min.) = 10
(max.) = 15%
Communications, limited to wireless communication and (S)
(min.) = 1
(max.) = 20%
Distribution System (S)
(min.) = 20,000 sf
(max.) = 60%
Nonres Use to Res (min.) = 10' or ¾(H)
Nonres Use to Nonres (min.) = (H)
Research and Product (P)
(min.) = 10,000 sf
(max.) = 50%
Nonres Use to Res (min.) = 10' or ¾(H)
Nonres Use to Nonres (min.) = (H)
Group Dwelling (P)
(min.) = 7,000 sf
(max.) = 70%
Nonres Use to Res (min.) = 10' or ¾(H)
Nonres Use to Nonres (min.) = (H)
•   Personal Storage (P)
•   Renewable Energy Generation (P)
Height (max.) = 16'
Nonres Use to Res (min.) = 10' or ¾(H)
Nonres Use to Nonres (min.) = (H)
C-2
Golf Course (P)
(min.) = 30
(max.) = 10%
Height (max.) = 25'
Nonres Use to Res (min.) = 2(H)
Correctional Use: Supervision Facility (P)
(min.) = 1
(max.) = 20%
Height (max.) = 25'
Nonres Use to Res (min.) = 2(H)
Billboard (P)
(min.) = 1,500 sf
Height (max.) = In accordance with Chapter 3, Sign Code, of the Tucson Code
Residence (P)
Height (max.) = 50'
Renewable Energy Generation (P)
Height (max.) = 16'
C-3
Golf Course (P)
(min.) = 30
(max.) = 10%
Height (max.) = 25'
Nonres Use to Res (min.) = 2(H)
Correctional Use: Supervision Facility (P)
(min.) = 1
(max.) = 20%
Height (max.) = 25'
Nonres Use to Res (min.) = 2(H)
Residential Care Services: Rehabilitation Service or Shelter Care (S)
Height (max.) = 40'
Billboard (P)
Lot Size (min.) = 1,500
Height (max.) = In accordance with Chapter 3, Sign Code, of the Tucson Code
Group Dwelling (P)
Height (max.) = 50'
Nonres Use adjacent to Res Zone (min.) = 1½(H)
•   Residential Care Services: Adult Care Service or Physical and Behavioral Health Service (P)
•   Residential Care Services: Rehabilitation Service - children’s facilities (P)
•   Residential Care Services: Rehabilitation Service or Shelter Care (P & S)
•   Residential Care Services: Shelter Care - victims of domestic violence (P)
Height (max.) = 40'
Nonres Use adjacent to Res Zone (min.) = 1½(H)
Renewable Energy Generation (P & S)
Height (max.) = 16'
OCR-1
Correctional Use: Supervision Facility (P)
(min.) = 1
(max.) = 20%
Height (max.) = 25'
Renewable Energy Generation (P & S)
Height (max.) = 16'
OCR-2
Correctional Use: Custodial Facility (S) Correctional Use: Supervision Facility (P)
(min.) = 1
(max.) = 20%
Height (max.) = 25'
Nonres Use to Res (min.) = 1½(H)
Residential Care Services: Rehabilitation Service or Shelter Care (P)
Height (max.) = 40'
Nonres Use to Res (min.) = 1½(H)
Renewable Energy Generation (P & S)
Height (max.) = 16'
 
Key:
Max. = Maximum permitted
Min. = Minimum requirement
P = Permitted Use
S = Special Exception Use
Uses without a “P” or “S” indicate the use is permitted within the