(A) Buildings and temporary structures built or located within the town from and upon the adoption of this subchapter shall be constructed in accordance with the requirements of the International Building Code (IBC), 2018 Edition, as published by the International Code Council (ICC), specifically excluding all appendices. Construction documents shall be designed and sealed by a Wyoming registered design professional.
(B) The said code is incorporated herein by reference as if the same were more fully herein set out except as follows.
(1) Section 101.1 Title. Delete (Name of Jurisdiction). Insert (Town of Star Valley Ranch).
(2) Section 101.4.3 Plumbing. The last sentence shall be deleted and replaced with. “The provisions of the Wyoming Department of Environmental Quality shall apply to private sewage disposal systems”.
(3) Section 101.4.4 Property maintenance. Shall be deleted in its entirety.
(4) Rescind 150.075 International Building Code (B)(4).
(5) Section 102.6 Existing structures. Delete International Property Maintenance Code in its entirety.
(6) Section 103.3 Deputies. The last sentence shall be deleted.
(7) Section 105.2 Work exempt from permit. Under Buildings paragraph 2, fences, shall be deleted in its entirety.
(11) Section 901.7 Rescind 150.075 International Building Code (B)(11).
(12) Section 903.2 Where required. A second sentence shall be added and shall read. “Additionally, all buildings and occupancies with a building area of 5000 square feet or larger on the main living floor shall be protected by an automatic sprinkler system designed and installed in accordance with Section 903.3.1 through 903.3.8.”
(13) Rescind 150.075 International Building Code (B)(13).
(14) Section 1301.1.1 Criteria. Delete in its entirety and insert Town Values.
Town Values | |
Building Location | |
Climate Zone | 7 |
Minimum Insulation R- Values
|
Minimum Insulation R- Values
| |
Maximum Glazing Factor | 0.35 Windows - 0.55 Skylights |
Ceilings | R-49 |
Walls | R-21 |
Floors | R21 |
Basement Walls | R-13 |
Slab Perimeter R-Value and Depth | R-13-36" |
Crawl Space Walls | R-10 |
(15) Section 1608.2 Ground snow loads. A sentence shall be added to read. “The flat roof snow load shall be 100 lbs. per sq. ft. for the Town of Star Valley Ranch, Wyoming.”
(16) Section 1809.4 Depth and width of footings. The minimum bearing depth of footings below the undisturbed ground surface shall be 36 inches unless a deeper depth is recommended by a geotechnical soil investigation. The minimum width of footings shall be 12 inches.
(17) Section 1805.1.2 Under floor space. The second sentence shall be revised to read. “Where there is evidence that the seasonal ground water table rises to the elevation of the crawl space, ground level, that the under-floor space shall be elevated to a minimum of 12 inches above such elevation unless an approved drainage system is provided.”
(18) Section 1809.12 Timber footings. Shall be deleted in its entirety.
(Prior Code, § 6.04.010) (Ord. 2022-14, passed 10-19-2022; Ord. 2023-05, passed 5-9-2023)