1711.01 ENACTMENT AND ADOPTION OF CODES.
   (a)    There is enacted and adopted by reference, for the purpose of establishing rules and regulations, the State Building Code as promulgated by the West Virginia State Fire Commission pursuant to West Virginia Code 29-3-5(b) and as by the State of West Virginia in Title 87, Legislative Rule Series 4 (§87-4-1 et seq.), State Building Code, as fully as if set forth at length in this section; and the provisions thereof shall be controlling within the designated limits of the City. One copy of the code, certified by the City Clerk, shall be maintained on file in the office of the Building Inspector of the City and shall be available to the public for inspection and use during all regular business hours.
   (b)    Any existing City ordinance that is more stringent or imposes a higher standard than is required by the above referenced codes shall govern, provided such ordinance is not inconsistent with the laws of West Virginia and is not contrary to recognized standards and good engineering practices.
   (c)   Any existing City ordinance that is less stringent or imposes a lower standard than is required by the above referenced codes is hereby amended to comply therewith:
   (d)    The following amendments (insertions into blank spaces) are made and incorporated into the codes adopted above:
TITLE 87
LEGISLATIVE RULE
STATE FIRE COMMISSION
SERIES 4
STATE BUILDING CODE
§87-4-1. General.
1.1. Scope. - This rule establishes the standards considered necessary by the States Fire Commission for the safe guarding of like and property and to ensure compliance with the minimum standards of safe construction of all structures erected or renovated throughout this state.
   
   1.2. Authority. -W. Va. Code §l5A-11-5.
   
   1.3. Filing Date. - May 5, 2022.
   
   1.4. Effective Date. - August 1, 2022.
1.5. Sunset Provision. - This rule shall terminate and have no further force or effect on August 1, 2027.
1.6. Exemptions. - The State building Code has no applications to buildings or structures used primarily for agricultural purposes including agritourist purpose.
1.7. Incorporation of Other Documents. -This rule does not include a reprinting of all the requirements imposed by statute or by incorporation of various nationally recognized standards and codes cited in Subsections 4.1 of this rule. For ascertaining these additional standards and requirements, it is necessary to make reference to the other documents.
§87-4-2. Definitions.
2.1. "ANSI" means American Nation Standards Institute, 25 West 43rd St., Fourth Floor, New York, NY 10036.
2.2. "ASTM" means American Society of Testing and Materials.
2.3. "Fire Commission" means the thirteen (13) appointed members of the West Virginia State Fire Commission.
2.4. "Fire Marshal" means the West Virginia State Fire Marshal and/or his or her designated representatives.
   2.5. "ICC" or " International" means International Code Council.
   2.6. "Local jurisdiction" means municipal, county, or other local government.
   2.7. "NFPA" means National Fire Protection Association.
2.8. "State Building Code" means the entire contents of this rule and the referenced national standards and codes.
2.9. "State Fire Code" means the entire contents of the State Fire Codes, 87CSR1, and the referenced states and codes.
§87-4-3. Conflicts.
3.1. Whenever there is a conflict between the State Fire Code and the State Building Code, the Fire Code takes precedence.
3.2. Whenever there is conflict between the International Plumbing Code requirements of the States Building Code and the rules of the West Virginia State Department of Health and Human Resources, the rules of the Department of Health and Human Resources take precedence.
3.3. Whenever there is a conflict between the States Building Code and the statutory laws of the State of West Virginia, the laws of the State of West Virginia take precedence.
§87-4-4. National Standards and Codes.
4.1. The standards and requirements as set out and as published by the International Code Council, and American National Standards Institute, and the National Fire Protection Association as listed in the subsection, have the same force and effect as if set out verbatim in this rule.
4.1.a.1. The 2018 edition, International Building Code, with the following exemptions
4.1.a.1. Provided: that the section entitled "Fire Prevention" and identified as Section 101.4.5 is deleted and not considered to be a part of this rule.
4.1.a.2 Further provided that the entire subsection entitled "Qualifications" and identified as Section 113.3 is deleted and replaced with the following:
         "Section 113.3 Board of Appeals
         113.3. Qualifications. The board of appeals shall consist of five members, with up to three alternates, who are qualified by experience and training to pass on matters pertaining to building construction and are not employees of the jurisdiction. They may include, but are not limited to, a WV Registered Professional Architect or Engineer, or a WV Licensed General Building, Residential, Electrical, Piping, Plumbing, Mechanical or Fire Protection Contractor, with a least 10 years experience, five of which shall be in responsible charge of work.
         No less than one of the members of such Board of Appeals shall be a WV Registered Professional Architect or Engineer, or a WV Licensed General Building Residential, Electrical, Piping, Plumbing, Mechanical or Fire Protection Contractor."
      4.1.b The 2018 edition of the International Plumbing Code.
4.1.c. The 2018 edition of the International Mechanical Code. The following shall be in addition to the current language found in the said edition of the reference code and section:
4.1.c.1. See International Mechanical Code, Section 908, Cooling Towers, Evaporative Condensers and Fluid Coolers.
      4.1.c.1.A 908.1 General- A cooling tower used in conjunction with an air-conditioning appliance shall be installed in accordance with the manufacturer's instructions. Factory-built cooling towers shall be listed in accordance with UL 1995 or UL/CSA 60335-2-40.
4.1.c.1.B. Section 916 Pool and Spa Heaters
4.1.c.1.B.1. 916.1 General -Pool and spa heater shall be installed in accordance with the manufacturer's instructions. Oil-fired pool and spa heaters shall be tested in accordance with UL 1261. Pool and spa heat pump water heaters shall comply with UL 1995, UI/CSA 60335-2-40 or CSA C22.2 No. 236 4.1.c.l .B.l.(a). Exception: Portable residential spas and portable residential exercise spas shall comply with UL 1563 or CSA C22.2 No. 218.l
      4.1.c.l.C. Section 918 Forced-Air Warm-Air Furnaces
         4.1.c.l.C.1. 918.1 Forced-Air furnaces- Oil-fired furnaces shall be tested in accordance with UL 727. Electric furnace shall be tested in accordance with UL 391. Forced-air furnaces shall be installed in accordance with the listings and the manufacturer's instructions.
         4.1.c.1.C.2. 1918.2 Heat Pumps-Electric heat pumps shall be tested in accordance with UL 1995 or UL/CSA 60335-2-40.
      4.1.c.l.D. Section 1101 General
      
         4.1.c.1.D.11101.2 Factory-Built Equipment and Appliances - Listed labeled self contained, factory-built equipment and appliances shall be tested in accordance with UL 207,412,471, 1995, UL/CSA 60335-2-4, UL/CSA 60335-2-89. Such equipment and appliances are deemed to the design, manufacture and factory test requirements of this code if installed in accordance with their listing and the manufacturer's instructions.
      4.1.c.l.E Chapter 15 REFERENCED STANDARDS
         4.1.c.1.E.1. 1501.3 References Standards- See Table 1
 
ASHREA                   ASHREA
                     1791 Tullie Circle, NE
                     Atlanta, GA 30329
                              
Standard
Reference
Number                  Title
15-2019            Safety Standard for Refrigeration Systems
34-2019            Designation and Safety Classification of Refrigerants
CSA               CSA Group
               8501 East Pleasant Valley Road
               Cleveland, OH 44313-5516
Standard
Reference
Number            Title
CSA C22.2 No. 60335-2-40-19   Household And Similar Electrical Appliances- Safety- Part 2-40:
               Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers- 3rd Edition
CSA C22.2 No. 60335-2-89-21   Household And Similar Electrical Appliances - Safety- Part 2-89:
               Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor
Table 1
 
UL                UL LLC
               333 Pfingsten Road
               Northbrook, IL 60062-2096
Standard
Reference
Number             Title
UL/CSA 60335-2-40-19      Household And Similar Electrical Appliances - Safety- Part
               2-40: Particular Requirements for Electrical Heat Pumps, Air Conditioners and Dehumidifiers - 3rd Edition
UL/CSA 60335-2-89-21      House And Similar Electrical Appliances - Safety- Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor
87CSR4
Table 1
4.1.d. The 2018 edition of the International Fuel Gas Code, with the following exception:
4.1.d.1. Section 404.10 Underground piping systems shall be installed a minimum depth of 12 inches (305 mm) below grade. If the minimum depth cannot be maintained, the piping system shall be installed in conduit or shielded in an approved manner.
4.1.e. The 2018 edition of the International Property Maintenance Code. This code may be rejected at the option of the local jurisdiction.
4.1.e.1 This code may be adopted by the local jurisdiction without requiring adoption of the other national codes and standards listed in the rule.
4.1.f. The 2015 edition of the International Energy Conservation Code for residential buildings, with the following exception:
4.1.f.1 Section, R402.4.1.2. Testing. The building or dwelling unit shall in lieu thereof have an air leakage rate not exceeding five air changes per hour in Climate Zones 3 through 8.
4.1.g. The ANSI/ASHRAE/IESNA Standard 90.1 2013 edition for commercial buildings.
4.1.g.1. Using building energy benchmarking in all commercial structures means measuring a building's energy use and then comparing it to the energy use of similar buildings, its own historical energy usage, or a reference performance level, and is an allowable option for improved energy efficiency and performance.
4.1.h. The 2018 edition of the International Residential Code for One- and Two-Family Dwellings, with the following exceptions:
4.1.h.1 Chapter 11 of the 2018 edition of the International Residential Code for One-and Two-Family Dwellings, Seventh Printing, entitled "Energy Efficiency", is exempt from this rule.
4.1.h.2. Section G2415.12 (404.10) Minimum Burial Depth. Underground piping systems shall be installed a minimum depth of 12 inches (305 mm) below grade. If the minimum depth cannot be maintained, the piping system shall be installed in conduit or shielded in an approved manner.
4.1.h.3. Section M1402 Central Furnaces.
4.1.h.3A. M1402.1 General-Oil-fired central furnaces shall conform to ANSI/UL 727. Electric furnaces shall conform to UL 1995 or UL/CSA 60335-2-40.
4.1.h.3.B. Section M1403 Heat Pump Equipment
4.1.h.3.B.1. M1403.l Heat pumps-Electric heat pumps shall be listed and labeled in accordance with UL 1995 or UL/CSA 60335-2-40.
4.1.h.3.C. Section M1412 Absorption Cooling Equipment
4.1.h.3.C.1. M1412.1 Approval of equipment- Absorption systems shall be installed
87CSR4
In accordance with the manufacturer's instructions. Absorption equipment shall comply with UL 1995 or UL/CSA 60335-2-40.
4.1.h.3.D. Section M1413 Evaporative Cooling Equipment
4.1.h.3.D.1. M1413.1 General-Evaporative cooling equipment and appliances shall comply with UL 1995 or UL/CSA 60335-2-40 and shall be installed in accordance with 4401.3 Referenced standard list:
4.1.h.3.E Chapter 44 Referenced standards
4.1.h.3.E.l. 4401.3 Referenced standard list- See table 2
 
ASHRAE
ASHRAE
1791 Tullie Circle NE
Atlanta, GA 30329
Standard referenced
Title
Table 2
34-2019:
Designation and Safety Classification of Refrigerants
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516
Standard referenced
Title
                     
 
CAN/CSA/C22.2 No.
60335-2-40-2019
UL
Safety of Household and Similar Electric
Appliances, Part 2-40; Particular
Requirements for Electrical Heat Pumps,
Air-Conditioners and Dehumidifiers-3rd
edition
UL LLC
333 Pfingsten Road
Northbrook, IL 60062
Standard referenced
Title
1995-2015:
Heating and Cooling Equipment
UL/CSA/
2-40-2019:
60335- Safety of Household and Similar
Electrical Appliances, Part 2-40:
Particular Requirements for Electrical
Heat Pumps, Air-Conditioners and
Dehumidifiers-3rd Edition
Table 2
               
87CSR4
4.1.i. Section R311.7.5 Stair Treads and Risers
4.1.i.1. 311.7.5.1 Riser Heights-The maximum riser height shall be eight and one quarter (8 1/4) inches.
4.1.i.2. 311.7.5.2 Tread Depth-The minimum tread depth shall be nine (9) inches.
4.1.j. Section R403.l.7.l: Building Clearances from Ascending Slopes is not applicable to this rule.
4.1.k. Section R403.1.7.2: Footings Setbacks from Descending Slope Surfaces is not applicable to this rule.
4.1.1.1. The 2018 International Existing Building Code, with the following exception:
4.1.1.2. Omit reference to International Fire Code and substitute NFPA Life Safety Code 2018 edition.
4.1.m. The 2020 edition of the National Electrical Code, NFPA 70, with the following exception:
4.1.m.1. Section 210.8(F) GFCI Protection shall not be required on all new mini-split heating/ventilation/air conditioning (HVAC) equipment and other HVAC units employing power conversion equipment as a means to control compressor speed systems including but not limited to mini-split and A/C units until January 1, 2023.
4.1.m.2. For renovations in one- and two-family homes where no new square footage is involved, arc-fault circuit interrupter (AFCI) protection shall not be required, except for in bedrooms. For renovation in one- and two-family homes where square footage is added but no electrical service is installed, arc-fault circuit interrupter (AFCI) protection shall not be required.
4.1.n. The 2018 edition of the International Swimming Pool and Spa Code.
4.2. Wherever referenced in the several ICC codes adopted in this section, any reference to the International Fire Code should be substituted with the NFPA Life Safety Code 2021 edition.
4.3. Whenever a certificate of occupancy is required of a commercial structure greater in size than 7,600 feet, the project documents shall be designed by an Architect licensed by the WV Board of Architects, or a Professional Engineer licensed by the WV State Board of Registration for Professional Engineers.
§ 87-4-5. Fire Protection of Floors in Residential Buildings
New One and Two Family Dwellings over one level in height, New One and Two Family Dwellings containing a crawl space containing a fuel burning appliance below the first floor, shall provide one of the following methods for fire protection of floors: (1) A½ inch (12.7mm) gypsum wallboard membrane, 5/8 inch (16mm) wood
87CSR4
structural panel membrane, or equivalent on the underside of the floor framing member; (2) Wood floor assemblies using dimension lumber or structural composite lumber equal or greater than 2 inch by 10 inch (50.8 mm by 254 mm) nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance; or (3) An Automatic Fire Sprinkler System as set forth in section R313.l or R313.2 of the 2015 edition of the International Residential Code for One and Two Family Dwellings: Provided, That floor assemblies located directly over a space protected by and automatic sprinkler system as set forth in section R313.l or R313.2 of the 2015 edition of the International Residential Code for One and Two Family Dwellings are exempt from this requirement.
5.2. Townhouses meeting the Fire-Resistant Construction Standard R302.2 will be treated as New One-and Two-Family Dwellings and shall comply with Section 5.1 above.
§87-4-6. Exceptions.
6.1. The following structures are not subject to inspection by local jurisdictions:
6.1.a. Group U utility structures and storage sheds comprising an area not more than 200 sq. ft. which have no plumbing or electrical connections and are used only for residential storage purposes. (Examples include sheds that are for the residential storage of lawnmowers, tools, bicycles or furniture.) Not included are those utility structures and storage sheds which have plumbing or electrical connections are a non-residential use or for the storage of explosives or other hazardous or explosive materials.
§ 87-4-7. Adoption by Local Jurisdiction.
7.1. Each local jurisdiction adopting the State Building Code shall notify the State Fire Commission in writing. The local jurisdiction shall send a copy of the ordinance or order to the State Fire Marshal, West Virginia State Fire Commission, 1207 Quarrier Street, 2nd floor, Charleston, West Virginia 25301, within thirty (30) days of adoption.
7.2. Each local jurisdiction which adopts the State Building Code is responsible for the enforcement of the building code as provided in West Virginia Code 7-1-3n and 8-12-13.
7.3. Throughout the national codes, adopted in subsection 4.1 of this rule, there are discretionary provisions or amendments which require further action by the adopting local jurisdiction in order to adapt these codes to various local conditions. The appendices are not a part of the code and must also be adopted by the local jurisdiction to be enforceable. It is therefore the intent of this rule to further authorize each local jurisdiction to further complete, by order or ordinance, those respective areas which are indicated to be completed by the adopting "jurisdiction" and any of the appendices the local jurisdiction wishes to adopt.
7.4. Within the penalty sections of each of the national codes, adopted in Section 4.1 of this rule, there is a penalty for imprisonment. The provision of imprisonment for any violation of this rule is optional with each adopting local jurisdiction.
7.5. Each of the national codes adopted in subsection 4.1 of this rule provides for a separate appeals board. However, the intent and requirements for and appeal board may be met with the creation by the local jurisdiction of a single appeals board for the entire "State Building Code."
7.6. Each local jurisdiction adopting the State Building Code shall comply with the requirements set forth in Title 87, Series 7 "Standards for the Certification and Continuing Education of Municipal, County, and Public-Sector Building Code Officials, Building Code Inspectors and Plans Examiners."
87CSR4
7.7. All questions of interpretation and enforcement of the State Building Code are delegated to the local jurisdiction unless expressly provided by State Code, by this Rule, or by the incorporated codes and standards referenced in this Rule.
§87-4-8. Existing Building Codes.
8.1. All building codes previously adopted by local jurisdictions are null and void.
9.1. If a property owner or other responsible party claims exemption from the applicable Building Code based on the agricultural purpose's exemption identified in subsection 1.6 of this rule, he or she shall submit the question to the Commissioner of Agriculture for a determination of eligibility.
9.2. The property owner or responsible party shall submit to the Commissioner of Agriculture sufficient information to allow the Commissioner to determine the primary use of the property. This information shall include, but is not limited to, the location of the property and buildings, the types of agricultural use or uses, the percentage or frequency of use, and any other information that the Commissioner requires to make a decision.
9.3. The Commissioner of Agriculture shall provide a copy of his or her decision to the property owner or responsible part, and to the entity that has adopted and is enforcing the Building Code.
   (e)    Nothing in this section hereby adopted shall be construed to affect any suit or proceeding impending in any court, or any rights acquired, or liability incurred, or any cause of action acquired or existing, under any provision hereby repealed; nor shall any right of remedy of any character be lost, impaired or affected by this chapter.
   (f)    The adoption of the City Building Code shall not be construed to affect or repeal any provisions of the Fire Prevention Code nor be construed as permitting a standard or gas piping and appliance venting on a customer's premises less than now or hereafter required by any natural gas utility.
   (g)    Whenever a certificate of occupancy is required of a commercial structure greater in size than 7,600 square feet, the project documents shall be designed by an Architect licensed by the WV Board of Architects, or a Professional Engineer licensed by the WV State Board of Registration for Professional Engineers.
(Ord. 2022-06. Passed 7-18-22.)