(a) The applicant shall install a 40-foot long culvert, as approved by the City Engineer, at each entrance or exit, to provide for a gravel cushion at the road edge to prevent berm and roadway destruction. Further, a gravel entry roadway, a minimum of 12 feet wide, shall be laid to the well site to reduce the amount of mud being carried to the right-of-way.
(b) The well, site shall be landscaped and maintained in a manner, approved by the City Council,
(c) All access roads shall be twelve feet in width and constructed and maintained in a manner to allow access to and egress from the well site by public safety vehicles under all climatic conditions.
(d) A steel culvert pipe, a minimum of 30 feet in length, shall be put in the drainage swale for access to the well site.
(Ord. 37-04. Passed 5-24-04.)