SECTION 3306 – PROTECTION OF PEDESTRIANS
3306.10  Add a section as follows:
3306.10  Chutes.  Chutes for the removal of materials and debris shall be provided in all parts of demolition operations that are more than 20 feet (6.096 m) above the point where the removal of material is effected. Such chutes shall be completely enclosed. They shall not extend in an unbroken line for more than 25 feet (7.62 m) vertically but shall be equipped at intervals of 25 feet (7.62 m) or less with substantial stops or offsets to prevent descending material from attaining dangerous speeds.
   The bottom of each chute shall be equipped with a gate or stop with a suitable means for closing or regulating the flow of material.
   Chutes, floors, stairways and other places affected shall be watered sufficiently to keep down the dust.
3306.11  Add a section as follows:
3306.11  Falling debris.  Wood or other construction materials shall not be allowed to fall in large pieces onto an upper floor. Bulky materials, such as beams and columns, shall be lowered and not allowed to fall.
3306.12  Add a section as follows:
3306.12  Structure stability.  In buildings of wood frame construction, the supporting structure shall not be removed until the parts of the structure being supported have been removed.