Skip to code content (skip section selection)
Compare to:
San Francisco Overview
San Francisco Building Inspection Commission (BIC) Codes
SAN FRANCISCO BUILDING INSPECTION COMMISSION CODES
BUILDING CODE 2016 Edition
PUBLISHER'S NOTE
PREFACE
Chapter 1 SCOPE AND ADMINISTRATION
Chapter 1A SAN FRANCISCO ADMINISTRATION
Chapter 2 DEFINITIONS
Chapter 3 USE AND OCCUPANCY CLASSIFICATION
Chapter 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Chapter 5 GENERAL BUILDING HEIGHTS AND AREAS
Chapter 6 TYPES OF CONSTRUCTION
Chapter 7 FIRE AND SMOKE PROTECTION FEATURES
Chapter 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
Chapter 8 INTERIOR FINISHES
Chapter 9 FIRE PROTECTION SYSTEMS
Chapter 10 MEANS OF EGRESS
Chapter 10A SECURITY REQUIREMENTS
Chapter 11 RESERVED
Chapter 11A HOUSING ACCESSIBILITY
Chapter 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLICLY FUNDED HOUSING
Chapter 11C RESERVED
Chapter 11D MANDATORY ACCESSIBILITY IMPROVEMENTS FOR BUILDINGS WITH A PLACE OF PUBLIC ACCOMMODATION
Chapter 12 INTERIOR ENVIRONMENT
Chapter 13 ENERGY EFFICIENCY
Chapter 13A COMMERCIAL WATER CONSERVATION
Chapter 13B CONSTRUCTION AND DEMOLITION DEBRIS RECOVERY PROGRAM
Chapter 13C [RESERVED]
Chapter 13D COMMERCIAL LIGHTING EFFICIENCY
Chapter 14 EXTERIOR WALLS
Chapter 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Chapter 16 STRUCTURAL DESIGN
Chapter 16A STRUCTURAL DESIGN
Chapter 17 SPECIAL INSPECTIONS AND TESTS
Chapter 17A SPECIAL INSPECTIONS AND TESTS
Chapter 18 SOILS AND FOUNDATIONS
Chapter 18A SOILS AND FOUNDATIONS
Chapter 19 CONCRETE
Chapter 19A CONCRETE
Chapter 20 ALUMINUM
Chapter 21 MASONRY
Chapter 21A MASONRY
Chapter 22 STEEL
Chapter 22A STEEL
Chapter 23 WOOD
Chapter 24 GLASS AND GLAZING
Chapter 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
Chapter 26 PLASTIC
Chapter 27 ELECTRICAL
Chapter 28 MECHANICAL SYSTEMS
Chapter 29 PLUMBING SYSTEMS
Chapter 30 ELEVATORS AND CONVEYING SYSTEMS
Chapter 31 SPECIAL CONSTRUCTION
Chapter 31A SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING MAINTENANCE
Chapter 31B [DPH] PUBLIC SWIMMING POOLS
Chapter 31C [DPH] RADIATION
Chapter 31D [DPH] FOOD ESTABLISHMENTS
Chapter 31E RESERVED
Chapter 31F [SLC] MARINE OIL TERMINALS
Chapter 32 ENCROACHMENTS INTO PUBLIC RIGHT-OF-WAY
Chapter 33 SAFEGUARDS DURING CONSTRUCTION
Chapter 34 RESERVED
Chapter 34A EXISTING STRUCTURES
Chapter 35 REFERENCED STANDARDS
Chapter 36 CALIFORNIA RESIDENTIAL CODE (CRC)
CALIFORNIA BUILDING CODE (CBC) APPENDICES
ADMINISTRATIVE BULLETINS
ELECTRICAL CODE 2016 Edition
EXISTING BUILDING CODE 2016 Edition
GREEN BUILDING CODE 2016 Edition
HOUSING CODE 2016 Edition
MECHANICAL CODE 2016 Edition
PLUMBING CODE 2016 Edition
Table of Amendments

You are viewing an archived code

Chapter 23
WOOD
SECTION 2304 – GENERAL CONSTRUCTION REQUIREMENTS
2304.12.1.5  Add the following second paragraph:
   Walls not accessible for maintenance shall have exterior covering of siding or plywood that are either treated wood or wood of natural resistance to decay. Plywood shall be exterior type, C-C Grade minimum, and not less than 1/2-inch (12.7 mm) thickness unless applied over sheathing. Plywood manufactured with redwood or cedar faces but with inner plys of other species conforming to DOC Standard PS1-95 may be used, provided the exposed outer face is plugged and not grooved or patterned.
2304.12.2.3  Add the following 2nd paragraph with exception, and 3rd paragraph:
   Weather-exposed stairways constructed with concrete, masonry, brick, tile or terrazzo shall be supported on hot-dipped galvanized steel or reinforced concrete stringers.
   EXCEPTION:  In Group R, Division 3 Occupancies, wood construction on masonry or concrete foundations may be used as supports, and the area under the stair shall be ventilated in compliance with 2304.12.7.
   Weather-exposed stairs of precast concrete or metal pan treads may be supported on wood stringers, provided the entire stairway is exposed and the treads are connected to the stringers by hot-dipped galvanized steel or other approved corrosion-resistant fasteners.
(Amended by Ord. 65-19, File No. 190136, App. 4/12/2019, Eff. 5/13/2019)
2304.12.3.2  Add the following section:
2304.12.3.2  Wood structural members.  Wood structural members that support moisture permeable floors or roofs that are exposed to the weather, such as concrete or masonry slabs, shall be of naturally durable or preservative-treated wood unless separated from such floors or roofs by an impervious moisture barrier extending up the walls not less than 4 inches (101.6 mm) or shall otherwise be adequately flashed and counter flashed.
   Regardless of finish flooring type or structural materials, the wood sub-floor of toilet rooms and bathrooms shall be protected by a waterproof membrane. Where a single ply sheet membrane is used, all adhesives shall be of a waterproof type and shall be applied so as to form a full unbroken coat between the backing and the membrane being applied. All seams and joints shall be thoroughly sealed.
   Exception: Interior floors in Group R, Division 3 Occupancies.
(Amended by Ord. 65-19, File No. 190136, App. 4/12/2019, Eff. 5/13/2019)