1137.23 SUBMISSION REQUIREMENTS FOR REVIEW BY THE DESIGN AND CONSTRUCTION BOARD OF REVIEW.
An application for review by the Design and Construction Board of Review, upon the forms provided, shall be accompanied by the following requirements:
   (a)   Site Plan: Drawn to scale, showing the lot size, building dimensions, front setback, side and rear setback dimensions, yard dimensions, walks and driveways, accessory structures, downspouts, drains and storm water disposal system. Show existing and proposed grade elevations if topography of lot is irregular or application is for a previously undeveloped lot. Locate patios, air conditioning condensers, swimming pools, retaining walls, fences, porches and other site improvements. Minimum scale: 1 inch equals 20 feet;
   (b)   Floor Plan: Drawn to scale, showing walls, windows, doors, and floor elevations. Minimum scale: 1/4 inch equals 1 foot;
   (c)   Foundation or Basement Plan: Drawn to scale, showing walls, windows, vents, doors, and floor elevations;
   (d)   Exterior Elevations: Elevations showing each side of the proposed building or addition, drawn to scale, showing downspout connections, chimney height, steps, platforms, etc. Minimum scale: 1/4 inch equals 1 foot;
   (e)   Heating Plan: Drawn to scale, showing the exterior location of all mechanical equipment or solar equipment. Air conditioning condensing unit must be shown on the site plan;
   (f)   Photographs. Photographs of the subject property and adjacent properties; and,
   (g)   Sample Building Materials. Color samples of roofing, siding and/or other exterior materials.