§ 11.19 EXTERIOR STRUCTURE.
   Subd. 1.   General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety, or welfare.
   Subd. 2.   Unsafe conditions. Any structural member or building component regulated by this ordinance that is deemed to be incapable of supporting all nominal loads or load effects due to deterioration, damage, neglect, inadequate anchorage, or other similar means shall be determined to be unsafe and shall be repaired, replaced, removed, or razed in accordance with the provisions of Minnesota State Building Code and city ordinance.
   Subd. 3.   The owner of any premises shall comply with the following requirements.
      A.   Structural members. Structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
      B.   Foundation walls. Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests.
      C.   Exterior walls. Exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration.
      D.   Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance.
      E.   Overhang extensions. Overhang extensions including, but not limited to, canopies, marquees, signs, metal awnings, fire escapes, standpipes, and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. Where required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
      F.   Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads.
      G.    Chimneys and towers. Chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. Exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
      H.   Window, skylight and doors. Every window, skylight, door, and frame shall be kept in sound condition, good repair and weather tight.
      I.   Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water.
   Subd. 4.   Premises identification. To ensure proper identification by emergency and other city staff, buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches in height with half-inch stroke.
(Ord. 69, Fourth Series, passed 4-6-2021)