All concrete used for any of the purposes set forth in this chapter shall:
(a) Contain a cement content of six and one-half bag mix at ninety-four pounds per bag of Portland cement;
(b) Have an air entrainment of six percent to eight percent at the time of pour;
(c) Consist of sound coarse aggregate one inch or smaller;
(d) Contain no more water than will permit a slump between a minimum of four inches and a maximum of six inches;
(e) Have a minimum thickness of four inches in the driveway and six inches in the apron from the property line to the curb or street line; and
(f) Be reinforced with wire reinforcing mesh having a maximum spacing of six inches in either parallel direction between the wires and a minimum wire size of number 10 U.S. gauge.
(Ord. 1984-112. Passed 7-5-84.)