§ 150.066 SPECIFIC STANDARDS.
   In all special flood hazard areas where BFE data has been provided, as set forth in § 150.031 or § 150.053, the following provisions, in addition to the provisions of § 150.065, are required:
   (A)   Residential construction. New construction or substantial improvement of any residential structure (including manufactured homes) will have the reference level, including basement, elevated no lower than the regulatory flood protection elevation, as defined in § 150.015.
   (B)   Nonresidential construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure must have the reference level, including basement, elevated no lower than the regulatory flood protection elevation, as defined in § 150.015. Structures located in Zones A, AE, AH, AO, A99 may be floodproofed to the regulatory flood protection elevation, in lieu of elevation, provided that all areas of the structure, together with attendant utility and sanitary facilities, below the regulatory flood protection elevation are watertight, with walls substantially impermeable to the passage of water, using structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. For AO Zones, the floodproofing elevation will be in accordance with § 150.071(B)(2). A registered, professional engineer or architect must certify that the floodproofing standards of this division (B) are satisfied. Such certification must be provided to the Floodplain Administrator as set forth in § 150.051(C), along with the operational plan and the inspection and maintenance plan.
   (C)   Manufactured homes.
      (1)   New or replacement manufactured homes must be elevated so that the reference level of the manufactured home is no lower than the regulatory flood protection elevation, as defined in § 150.015.
      (2)   Manufactured homes must be securely anchored to an adequately anchored foundation to resist flotation, collapse and lateral movement, either by a certified engineered foundation system, or in accordance with the most current edition of the State of North Carolina Regulations for Manufactured Homes, adopted by the Commissioner of Insurance pursuant to G.S. § 143-143.15. Additionally, when the elevation would be met by an elevation of the chassis 36 inches or less above the grade at the site, the chassis shall be supported by reinforced piers or engineered foundation. When the elevation of the chassis is above 36 inches in height, an engineering certification is required.
      (3)   All enclosures or skirting below the lowest floor shall meet the requirements of division (D) below.
      (4)   An evacuation plan must be developed for evacuation of all residents of all new, substantially improved or substantially damaged manufactured home parks or subdivisions located within flood-prone areas. This plan shall be filed with and approved by the Floodplain Administrator and the local Emergency Management Coordinator.
   (D)   Elevated buildings. A fully enclosed area of new construction and substantially improved structures, which is below the lowest floor or below the lowest horizontal structural member in VE Zones:
      (1)   Must not be designed or used for human habitation, but must only be used for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door), limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). The interior portion of the enclosed area must not be finished or partitioned into separate rooms, except to enclose storage areas;
      (2)   Must be constructed entirely of flood-resistant materials at least to the regulatory flood protection elevation; and
      (3)   Must include, in Zones A, AE, AH, AO, A99, flood openings to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters. To meet this requirement, the openings must either be certified by a professional engineer or architect, or meet or exceed the following minimum design criteria:
         (a)   A minimum of two flood openings on different sides of each enclosed area subject to flooding;
         (b)   The total net area of all flood openings must be at least one square inch for each one square foot of enclosed area subject to flooding;
         (c)   If a building has more than one enclosed area, each enclosed area must have flood openings to allow floodwaters to automatically enter and exit;
         (d)   The bottom of all required flood openings will be no higher than one foot above the higher of the interior or exterior adjacent grade;
         (e)   Flood openings may be equipped with screens, louvers, or other coverings or devices, provided they permit the automatic flow of floodwaters in both directions; and
         (f)   Enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require flood openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires flood openings as outlined above.
   (E)   Additions/improvements.
      (1)   Additions and/or improvements to pre-FIRM structures, when the addition and/or improvements, in combination with any interior modifications to the existing structure, are:
         (a)   Not a substantial improvement, the addition and/or improvements must be designed to minimize flood damages, and must not be any more nonconforming than the existing structure; and
         (b)   A substantial improvement, with modifications/rehabilitations/improvements to the existing structure or the common wall is structurally modified more than installing a doorway, both the existing structure and the addition must comply with the standards for new construction.
      (2)   Additions to pre-FIRM or post-FIRM structures that are a substantial improvement, with no modifications/rehabilitations/improvements to the existing structure other than a standard door in the common wall, will require only the addition to comply with the standards for new construction.
      (3)   Additions and/or improvements to post-FIRM structures, when the addition and/or improvements, in combination with any interior modifications to the existing structure, are:
         (a)   Not a substantial improvement, the addition and/or improvements only must comply with the standards for new construction consistent with the code and the requirements for the original structure; or
         (b)   A substantial improvement, both the existing structure and the addition and/or improvements must comply with the standards for new construction.
      (4)   Any combination of repair, reconstruction, rehabilitation, addition or improvement of a building or structure taking place during a one-year period, the cumulative cost of which equals or exceeds 50% of the market value of the structure before the improvement or repair is started, must comply with the standards for new construction. For each building or structure, the one-year period begins on the date of the first improvement or repair of that building or structure subsequent to the effective date of this chapter. SUBSTANTIAL DAMAGE also means flood-related damage sustained by a structure on two separate occasions during a ten-year period for which the cost of repairs at the time of each such flood event, on the average, equals or exceeds 25% of the market value of the structure before the damage occurred. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The requirement does not, however, include either:
         (a)   Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the Building Official, and that are the minimum necessary to assure safe living conditions; or
         (b)   Any alteration of a historic structure, provided that the alteration will not preclude the structure's continued designation as a historic structure.
   (F)   Recreational vehicles. Recreation vehicles placed on sites within a special flood hazard must either:
      (1)   Temporary placement.
         (a)   Be on site for fewer than 180 consecutive days; or
         (b)   Be fully licensed and ready for highway use. (A recreational vehicle is READY FOR HIGHWAY USE if it is on its wheels or jacking system, is attached to the site only by quick disconnect-type utilities and has no permanently attached additions.)
      (2)   Permanent placement. Recreational vehicles that do not meet the limitations of temporary placement must meet all the requirements for new construction.
   (G)   Temporary nonresidential structures. Prior to the issuance of a floodplain development permit for a temporary structure, the applicant must submit to the Floodplain Administrator a plan for the removal of such structure(s) in the event of a hurricane, flash flood, or other type of flood warning notification. The following information shall be submitted in writing to the Floodplain Administrator for review and written approval:
      (1)   A specified time period for which the temporary use will be permitted. Time specified may not exceed three months, renewable up to one year;
      (2)   The name, address and phone number of the individual responsible for the removal of the temporary structure;
      (3)   The time frame prior to the event at which a structure will be removed (i.e., minimum of 72 hours before landfall of a hurricane or immediately upon flood warning notification);
      (4)   A copy of the contract or other suitable instrument with the entity responsible for physical removal of the structure; and
      (5)   Designation, accompanied by documentation, of a location outside the special flood hazard area to which the temporary structure will be moved.
   (H)   Accessory structures.
      (1)   When accessory structures (sheds, detached garages, etc.) are to be placed within a special flood hazard area, the following criteria must be met;
         (a)   Accessory structures must not be used for human habitation (including work, sleeping, living, cooking or restroom areas);
         (b)   Accessory structures must not be temperature-controlled;
         (c)   Accessory structures must be designed to have low flood damage potential;
         (d)   Accessory structures must be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters;
         (e)   Accessory structures must be firmly anchored in accordance with § 150.065(A);
         (f)   All service facilities, such as electrical must be installed in accordance with § 150.065(D); and
         (g)   Flood openings, to facilitate automatic equalization of hydrostatic flood forces, must be provided below regulatory flood protection elevation in conformance with the provisions of division (D)(3) above.
      (2)   An accessory structure, which has a footprint of 150 square feet or less, or is an minimal investment of $3,000 or less, and satisfies the criteria outlined in division (H)(1) above, and is not required to meet the elevation or floodproofing standards of division (B) above. Elevation or floodproofing certifications are required for all other accessory structures in accordance with § 150.051(C).
   (I)   Tanks. When gas and liquid storage tanks are to be placed within a special flood hazard area, the following criteria shall be met.
      (1)   Underground tanks. Underground tanks in flood hazard areas shall be anchored to prevent flotation, collapse or lateral movement resulting from hydrodynamic and hydrostatic loads during conditions of the design flood, including the effects of buoyancy, assuming the tank is empty;
      (2)   Aboveground tanks, elevated. Aboveground tanks in flood hazard areas shall be elevated to or above the regulatory flood protection elevation, on a supporting structure that is designed to prevent flotation, collapse or lateral movement during conditions of the design flood. Tank-supporting structures must meet the foundation requirements of the applicable flood hazard area;
      (3)   Aboveground tanks, not elevated. Aboveground tanks that do not meet the elevation requirements of § 150.066(B) maybe permitted in flood hazard areas, provided the tanks are designed, constructed, installed and anchored to resist all flood-related and other loads, including the effects of buoyancy, during conditions of the design flood, and without release of contents in the floodwaters, or infiltration by floodwaters into the tanks. Tanks shall be designed, constructed, installed and anchored to resist the potential buoyant and other flood forces acting on an empty tank during design flood conditions.
      (4)   Tank inlets and vents. Tank inlets, fill openings, outlets and vents must be:
         (a)   At or above the regulatory flood protection elevation, or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the design flood; and
         (b)   Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the design flood.
   (J)   Other development.
      (1)   Fences in regulated floodways and NEAs that have the potential to block the passage of floodwaters, such as stockade fences and wire-mesh fences, shall meet the limitations of § 150.070.
      (2)   Retaining walls, sidewalks and driveways in regulated floodways and NEAs. Retaining walls and sidewalks and driveways that involve the placement of fill in regulated floodways will meet the limitations of § 150.070.
      (3)   Roads and watercourse crossings in regulated floodways and NEAs. Roads and watercourse crossings, including roads, bridges, culverts, low-water crossings, and similar means for vehicles or pedestrians to travel from one side of a watercourse to the other side, that encroach into regulated floodways, must meet the limitations of § 150.070.
      (4)   Commercial storage facilities are not considered "limited storage" as noted in this chapter, and will be protected to regulatory flood protection elevation as required for commercial structures.
(Ord. passed 7-15-2003; Ord. 2019-09, passed 9-12-2019; Ord. 2020-02, passed 6-11-2020)