§ 155.084 SIDEWALKS AND PEDESTRIAN WAYS.
   All required walks shall be concrete four inches thick. Grades shall be as approved by the City Engineer. Sidewalks shall be placed in the public right-of-way.
(Ord. 179, passed 2-16-78)
§ 155.085 PUBLIC UTILITIES.
   (A)   Water main. A minimum water main of six-inch ductile iron pipe or other approved pipe shall be required. Mains over six inches in diameter may be required and the city may participate in the cost of the required oversizing.
   (B)   Sanitary sewer. A minimum sanitary sewer of eight inches in diameter S.D.R.-35 plastic pipe, or other approved pipe, shall be required. Mains over eight inches in diameter may be required and the city may participate in the cost of the required oversizing. Service wyes shall be four inches, or as required by the Engineer.
   (C)   House services. Each house service shall be run from the main to the property line where a cap or plug shall be placed until the service is extended to the structure. A two-inch by two-inch location stake shall be placed at the end of the house service and within six inches of ground surface.
   (D)   Storm sewer. A minimum storm sewer of 12 inches in diameter of R.C.P. Class 3, or other approved pipe, shall be required.
(Ord. 179, passed 2-16-78)
§ 155.086 ON-SITE SEWAGE DISPOSAL SYSTEMS.
   (A)   Where lots cannot be connected with a public sewerage system, provisions must be made for sanitary sewer facilities, consisting of individual disposal systems for each lot. This does not mean that the installation of individual disposal systems shall be at the expense of the subdivider.
   (B)   Any subdivision or lot not provided with off-site sewer facilities shall be subject to soil and percolation tests to determine whether or not the lot size proposed will meet minimum standards of health and sanitation if requested by the Planning Commission. The lot area and topography must be such that it will accommodate an adequate disposal system or systems to serve the residence for the estimated unsewered years as determined by the City Council. These tests shall be made at the expense of the subdivider, and a sketch map shall be submitted to identify the specific locations where tests were made.
   (C)   All proposed on-site sewage disposal systems shall comply with the regulations and recommended standards of the state Department of Health, state Pollution Control Agency, and the city, and any other applicable governmental regulations.
(Ord. 179, passed 2-16-78)
§ 155.087 WATER SUPPLY.
   Public water facilities shall be utilized where available. Water supply systems for all other areas shall be designed to meet regulations and recommended standards of the State Department of Health and the city.
(Ord. 179, passed 2-16-78)
§ 155.088 DRAINAGE.
   All surface and underground drainage systems shall be installed to adequately remove all natural drainage that accumulates on the developed property. All these systems shall be in conformity to the city’s drainage plans and all piping shall provide adequate removal and a permanent solution for the removal of drainage water.
(Ord. 179, passed 2-16-78)
§ 155.089 STREET SIGNS, LIGHTING, AND TRAFFIC CONTROLS.
   All street signs of standard design approved by the city shall be provided and installed by the subdivider. Street lighting of standard design and approved by the city and the electric utility serving the area shall be provided and installed by the subdivider. All traffic controls of standard design, approved by the city and, where applicable, other municipality and/or the state, shall be provided and installed by the subdivider.
(Ord. 179, passed 2-16-78)
§ 155.090 CURBS AND GUTTERS.
   A concrete curb and gutter including curb cuts and driveway approaches of a design approved by the City Engineer shall be installed by the subdivider on each side of the streets indicated in the plat.
(Ord. 179, passed 2-16-78)