The following development standards shall apply to I-1 districts:
(a) Development standards.
Minimum lot area | 2 acres |
Maximum building height (a) | 40 feet |
Minimum Setback
| |
Structures NOT abutting a residential district (a) | |
Front (b) | 25 feet |
Side | 12 feet |
Rear | 10 feet |
Structures abutting a residential district (a) | |
Front | 50 feet |
Side and rear | 100 feet |
Parking structures or paved areas | |
Front (c) | 25 feet |
Side and rear | 10 feet |
(a) Minimum setbacks are for structures up to 40 feet in height. For each additional foot in height, the setback shall increase by two feet. No building shall exceed 90 feet in height. | |
(b) For lots fronting on two streets, the front setback shall apply to both yards abutting the street right-of-way. | |
(c) Excludes areas required for access to street. | |
(b) Off-street parking and loading. Off-street parking and loading facilities shall be provided as specified in Chapter 1175.
(c) Storage and unloading. The storage of raw materials and/or manufactured products shall be behind the rear of the building and shall be sufficiently screened from view from the roadway and the adjoining properties as determined by the Planning Commission to be necessary to conceal the storage from view. Loading and unloading operations shall be conducted in the rear or side of the building and shall be sufficiently screened from view from the roadway and the adjoining properties as determined by the Planning Commission to be necessary to conceal the loading and unloading operations from view.
(d) Exterior building material.
(1) Unfinished or unpainted non-decorative concrete block shall not be used on any exterior wall.
(2) Metal siding shall not be used on any wall facing a public street or a residential district. If metal siding is utilized on any remaining wall, it shall be subject to the approval of Planning Commission.
(3) A combination of brick, masonry, glass, architectural metal wall panels, or other suitable building materials shall be used on the front facade of the building, subject to the Planning Commission approval.
(e) Mechanical screening. All roof mounted mechanical equipment shall be screened from view from all adjacent property and zoning districts and from road rights-of-way in all zoning districts using durable, compatible, opaque materials.
(Ord. 2004-155, passed 1-10-2005; Ord. 2015-89, passed 9-28-2015)