§ 51.27 LARGE INDUSTRIAL HIGH LOAD FACTOR (HLF) RATE SCHEDULE.
   (A)   Designation. Large Industrial High Load Factor (HLF) Rate Schedule.
   (B)   Availability. In any area served by the Madisonville Municipal Utilities (MMU) electric system in accordance with MMU’s terms and conditions for providing electric service.
   (C)   Application. To any large power customer for all electric power and energy requirements that do not fall below 1,500 kW and 60% load factor for more than one month within a 12- month period. In addition, the customer shall contract for year-round permanent service, and shall provide satisfactory guarantees or contributions to construction to satisfy the expenditure necessary to provide the desired service. Each premises will be supplied only at one point of delivery and all electric service supplied will be measured through one meter. This schedule is not applicable for temporary, breakdown, standby, supplementary, resale or shared electric service.
   (D)   Type of service. Three phase, 60 hertz, with secondary voltages of 120/208, 120/240, 277/480, primary voltages of 7200/12470, or other voltages as might be mutually agreeable.
   (E)   Monthly Rate.
      (1)   Customer charge: $549.24 per month
      (2)   Demand charge: $11.94 per KW for each KW Billing Demand Energy
       (3)   Charge: $0.06132 cents per KWH
   (F)   Billing demand. Billing demand shall be greater of:
      (1)   The maximum fifteen (15) minute peak demand (kW) measured during the billing month;
      (2)   Sixty percent (60%) of the highest demand established in the preceding eleven (11) months; or
      (3)   Twenty percent (20%) of customer’s Contract Demand (kW).
   (G)   Minimum bill. The minimum billing charge under the above rate shall be the Customer Charge plus a facilities investment charge of $1.00 per kVA of installed transformer capacity as requested by the customer.
   (H)   Power factor. This rate schedule is subject to a Power Factor Charge as defined in the customer’s Energy Services Contract and /or this rate schedule.
   (I)   Fuel Cost Adjustment and Power Cost Adjustment. The above rates are subject to a Fuel Adjustment Cost (FAC) and/or a Power Cost Adjustment (PCA) as specified in MMU’s Rules and Regulations.
(Ord. 09-15, passed 12-7-09; Am. Ord. O-2022-11, passed 6-6-22)
Cross reference:
   Large General Services GS-2, see § 51.13