Loading...
(A) The Floodplain Administrator and/or staff is hereby appointed, authorized and directed to administer, implement and enforce the provisions of this chapter. The Floodplain Administrator is further authorized to render interpretations of this chapter, which are consistent with its spirit and purpose by granting or denying development permits in accordance with its provisions.
(B) The duties and responsibilities of the Floodplain Administrator shall include, but not be limited to the following:
(1) Permit review. Review all development permits to ensure that:
(a) Permit requirements of this chapter have been satisfied;
(b) All other required state and federal permits have been obtained: Advise permittee that additional federal or state permits may be required, and if specific federal or state permit requirements are known, require that copies of such permits be provided and maintained on file with the development permit;
(c) Flood damages will be reduced in the best possible manner;
(d) The proposed development docs not adversely affect the carrying capacity of affected watercourses. For purposes of this chapter, “adversely affects” means that the cumulative effect of the proposed development when combined with all other existing and anticipated development will increase the water surface elevation of the base flood more than one foot at any point.
(2) Review and use of any other base flood data. When base flood elevation data has not been provided in accordance with § 157.07, and the Floodplain Administrator shall obtain, review, and reasonably utilize any base flood elevation and flood way data available from a federal or state agency, or other source, in order to administer §§ 157.30 et seq. Any such information shall be submitted to the City Council for adoption.
(3) Notification of Other Agencies.
(a) Notify adjacent communities, the Kentucky Division of Water, and any other federal and/or state agencies with statutory or regulatory authority prior to any alteration or relocation of the watercourse, and
(b) Submit evidence of such notification to the Federal Insurance Administration, Federal Emergency Management Agency (FEMA); and
(c) Assure that the flood carrying capacity within the altered or relocated portion of said watercourse is maintained.
(4) Documentation of Floodplain Development. Obtain and maintain for public inspection and make available as needed the following:
(a) Certification required by § 157.31(A) (lowest floor elevations) as shown on a completed and certified Elevation Certificate. Verify and record the actual elevation (in relation to Mean Sea Level) of the lowest floor (including basement) of all new or substantially improved structures, in accordance with § 157.21(B)(2);
(b) Certification required by § 157.31(B) (elevation or floodproofing of nonresidential structures) as shown on a completed and certified floodprooofing certificate. Verify and record the actual elevation (in relation to Mean Sea Level) to which the new or substantially improved structures have been flood-proofed, in accordance with § 157.21(B)(2);
(c) Certification required by § 157.31(C) (elevated structures);
(d) Certification of elevation required by § 157.34(A) (subdivision standards);
(e) Certification required by § 157.31(E) (floodway encroachments),
(f) Assure that maintenance is provided within the altered or relocated portion of said watercourse so that the flood-carrying capacity is not diminished;
(g) Review certified plans and specifications for compliance;
(5) Map, determinations. Make interpretations where needed, as to the exact location of the boundaries of the special flood hazard areas, for example, where there appears to be a conflict between a mapped boundary and actual field conditions.
(a) Where interpretation is needed as to the exact location of boundaries of the areas of special flood hazard (for example, where there appears to be a conflict between a mapped boundary and actual field conditions) the Floodplain Administrator shall make the necessary interpretation. The person contesting the location of the boundary shall be given a reasonable opportunity to appeal the interpretation as provided in § 157.46(B)(2);
(b) When base flood elevation data or floodway data have not been provided in accordance with § 157.21, then the Floodplain Administrator shall obtain, review, and reasonable utilize any base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of §§ 157.30 et seq.;
(c) When flood-proofing is utilized for a particular structure, the Floodplain Administrator shall obtain certification from a registered professional engineer or architect, in accordance with § 157.31(B) a floodproofing certificate;
(d) All records pertaining to the provisions of this chapter shall be maintained in the office of the Floodplain Administrator and shall be open for public inspection.
(6) Right of entry.
(a) Whenever necessary to make an inspection to enforce any of the provisions of this chapter, or whenever the administrator has reasonable cause to believe that there exists in any structure or upon any premises any condition or ordinance violation which makes such building, structure or premises unsafe, dangerous or hazardous, the administrator may enter such building, structure or premises at all reasonable times to inspect the same or perform any duty imposed upon the administrator by this chapter.
(b) If such structure or premises are occupied, he/she shall first present proper credentials and request entry. If such building, structure, or premises are unoccupied, he shall first make a reasonable effort to locate the owner or other persons having charge or control of such request entry.
(c) If entry is refused, the administrator shall have recourse to every remedy provided by law to secure entry.
(d) When the administrator shall have first obtained a proper inspection warrant or other remedy provided by law to secure entry, no owner or occupant or any other persons having charge, care or control of any building, structure, or premises shall fail or neglect, after proper request is made as herein provided, to promptly permit entry therein by the administrator for the purpose of inspection and examination pursuant to this chapter.
(7) Scop work orders.
(a) Upon notice from the administrator, work on any building, structure or premises that is being done contrary to the provisions of this chapter shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to his agent, or to the person doing the work, and shall state the conditions under which work may be resumed.
(8) Revocation of permits.
(a) The administrator may revoke a permit or approval, issued under the provisions of this chapter, in case there has been any false statement or misrepresentation as to the material fact in the application or plans on which the permit or approval was based;
(b) The administrator may revoke a permit upon determination by the administrator that the construction, erection, alteration, repair, moving, demolition, installation, or replacement of the structure for which the permit was issued is in violation of, or not in conformity with, the provisions of this chapter.
(9) Liability. Any officer, employee, or member of the floodplain administrator's staff, charged with the enforcement of this chapter, acting for the applicable governing authority in the discharge of his duties, shall not thereby render himself personally liable, and is hereby relieved from all personal liability, for any damage that may accrue to persons or property as a result of any act required or permitted in the discharge of his duties. Any suit brought against any officer, employee, or member because of such act performed by him or her in the enforcement of any provision of this chapter shall be defended by the department of law until the final termination of the proceedings.
(10) Expiration of floodplain construction permit. A floodplain construction permit, and all provisions contained therein, shall expire if the holder of a floodplain construction permit has not commenced construction within one hundred and 80 calendar days from the date of its issuance by the Floodplain Administrator.
(Ord. 2008-03, passed 4-21-08)
PROVISIONS FOR FLOOD HAZARD REDUCTION
In all special flood hazard areas the following provisions are required:
(A) All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy;
(B) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors.This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces.
(C) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage;
(D) New construction and substantial improvements shall be constructed by methods and practices that minimize flood damage;
(E) Electrical, heating, ventilation, plumbing, air condition equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and if
(F) Within Zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures;
(G) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system;
(H) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters;
(I) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding; and
(J) Any alteration, repair, reconstruction, or improvements to a structure, which is not in compliance with the provisions of this chapter shall meet the requirements of “new construction” as contained in this chapter;
(K) Any alteration, repair, reconstruction, or improvements to a structure, which is not in compliance with the provisions of this chapter, shall be undertaken only if said non-conformity is not furthered, extended, or replaced.
(Ord. 2008-03, passed 4-21-08)
In all special flood hazard areas where base flood elevation data have been provided, as set forth in § 157.07, the following provisions are required:
(A) Residential construction. New construction or substantial improvement of any residential structure (or manufactured home) shall have the lowest floor, including basement, mechanical equipment, and ductwork elevated no lower than two feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of division (C).
(1) In an AO zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified.
(2) In an A zone, where no technical data has been produced by the Federal Emergency Management Agency, elevated two feet above the base flood elevation, as determined by this community. The Floodplain Administrator will determine the method by which base flood elevations are determined. Methods include but are not limited to detailed hydrologic and hydraulic analyses, use of existing data available from other sources, use of historical data, best supportable and reasonable judgment in the event no data can be produced. Title 401 KAR (Kentucky Administrative Regulations) Chapter 4, Regulation 060, states as a part of the technical requirements for a State Floodplain Permit. The applicant shall provide cross sections for determining floodway boundaries (and thereby Base Flood Elevations) at any proposed construction site where FEMA maps are not available. All cross sections shall be referenced to mean sea level and shall have vertical error tolerances of no more than 0.5 foot. Cross sections elevations shall be taken at those points which represent significant breaks in slope and at points where hydraulic characteristics of the base floodplain change. Each cross section shall extend across the entire base floodplain and shall be in the number and at the locations specified by the cabinet. If necessary to ensure that significant flood damage will not occur, the cabinet may require additional cross sections or specific site elevations which extend beyond those needed for making routine regulatory floodway boundary calculations.
(3) In all other zones, elevated two feet above the base flood elevation.
(4) Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community building inspection department to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator.
(B) Non-residential construction. New construction or substantial improvement of any commercial, industrial, or non-residential structure (including manufactured homes used for non-residential purposes) shall be elevated to conform with division (A) or together with attendant utility and sanitary facilities:
(1) Be flood proofed below an elevation two feet above the level of the base flood elevation so that the structure is watertight with walls substantially impermeable to the passage of water;
(2) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy;
(3) Have the lowest floor, including basement, mechanical equipment, and ductwork, elevated no lower than two feet above the level of the base flood elevation; or
(4) A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in § 157.31(A)(1)(c).
(5) Manufactured homes shall meet the standards in § 157.31(D).
(6) All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be constructed of flood resistant materials below an elevation two feet above the base flood elevation, and, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Opening sizes (FEMA Technical Bulletin 1-93) for meeting this requirement must meet or exceed the following minimum criteria:
(a) Be certified by a registered professional engineer or architect; or
(b) Have a minimum of two openings with a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater.
(C) Elevated structures. New construction or substantial improvements of elevated structures on columns, posts, or pilings (e.g.) that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters lo automatically equalize hydrostatic flood forces on exterior walls.
(1) Opening sizes for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria;
(a) Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding;
(b) The bottom of all openings shall be no higher than one foot above foundation interior grade (which must be equal to in elevation or higher than the exterior foundation grade); and
(c) Openings may be equipped with screens, louvers, valves, or other coverings or devices provided they permit the automatic flow of floodwaters in both directions.
(2) Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and
(3) The interior portion of such enclosed areas shall not be partitioned or finished into separate rooms.
(D) Standards for manufactured homes and recreational vehicles.
(1) (a) All new or substantially improved manufactured homes placed on sites located within A, A1-30, AO, AH, and AE on the community's Flood Insurance Rate Map (FIRM) must meet all the requirements for new construction, including elevation and anchoring. Locations include:
1. On individual lots or parcels;
2. In expansions to existing manufactured home parks or subdivisions;
3. In new manufactured home parks or subdivisions;
4. In substantially improved manufactured home parks or subdivisions; or
5. Outside of a manufactured home park or subdivision;
6. In an existing manufactured home park or subdivision on a site upon which a manufactured home has incurred “substantial damage” as the result of a flood.
(b) All manufactured homes must be:
1. Elevated on a permanent foundation; and
2. Have its lowest floor elevated no lower than two feet above the level of the base flood elevation; and
3. Be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.
(2) Except manufactured homes that have incurred substantial damage as a result of a flood, all manufactured homes placed or substantially improved in an existing manufactured home park or subdivision must be elevated so that:
(a) The manufactured home is securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement, so that either the:
1. The lowest floor of the manufactured home is elevated no lower than two feet above the level of the base flood elevation; or
2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above the highest adjacent grade.
(3) All recreational vehicles placed on sites located within A, A1-30, AO, AH. and AE on the community's Flood Insurance Rate Map (FIRM) must either:
(a) Be on the site for fewer than 180 consecutive days;
(b) Be fully licensed and ready for highway use; or
(c) Meet the permit requirements for new construction of this chapter, including anchoring and elevation requirements for “manufactured homes”.
(4) A recreational vehicle is ready for highway use if it is licensed and insured in accordance with the state motor vehicle regulations, is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions.
(E) Floodways. Located within areas of special Hood hazard established in § 157.07, are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and has erosion potential, the following provisions shall apply;
(1) Prohibit encroachments, including fill, new construction, substantial improvements, and other developments unless certification (with supporting technical data) by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in the base flood elevation levels during occurrence of base flood discharge;
(2) If this division (E) is satisfied, all new construction and substantial improvements and other proposed new development shall comply with all applicable flood hazard reduction provisions of §§ 157.30 et seq.
(Ord. 2008-03, passed 4-21-08)
Located within the special flood hazard areas established in § 157.07, where streams exist but where no base flood data has been provided or where base flood data has been provided without floodways, the following provisions apply:
(A) No encroachments, including fill material or structures shall be located within special flood hazard areas, unless certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development will not increase the water surface elevation of the base flood more than one foot at any point within the community. The engineering certification should be supported by technical data that conforms to standard hydraulic engineering principles.
(B) New construction or substantial improvements of structures shall be elevated or flood proofed to elevations established in accordance with § 157.07.
(Ord. 2008-03, passed 4-21-08)
Located within the special flood hazard areas established in § 157.07, are areas designated as shallow flooding areas. These areas have flood hazards associated with base flood depths of one to three feet, where a clearly defined channel does not exist and the water path of flooding is unpredictable and indeterminate; therefore, the following provisions apply:
(A) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to or above either the base flood elevation or in Zone AO the flood depth specified on the Flood Insurance Rate Map above the highest adjacent grade. In Zone AO, if no flood depth is specified, the lowest floor, including basement, shall be elevated no less than two feet above the highest adjacent grade.
(B) All new construction and substantial improvements of non-residential structures shall:
(1) Have the lowest floor, including basement, elevated to or above either the base flood elevation or in Zone AO the flood depth specified on the Flood Insurance Rate Map, above the highest adjacent grade. In Zone AO, if no flood depth is specified, the lowest floor, including basement, shall be elevated no less than two feet above the highest adjacent grade.
(2) Together with attendant utility and sanitary facilities be completely flood-proofed either to the base flood elevation or above or, in Zone AO, to or above the specified flood depth plus a minimum of one foot so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Certification is required as stated in § 157.31(B).
(Ord. 2008-03, passed 4-21-08)
(A) All preliminary subdivision proposals shall identify the flood hazard area and the elevation of the base flood and be consistent with the need to minimize flood damage;
(B) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage;
(C) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and,
(D) In areas where base flood elevation and floodway data is not available (Zone A or unmapped streams), base flood elevation and floodway data for subdivision proposals and other proposed development (including manufactured home parks and subdivisions) greater than 50 lots or five acres, whichever is the lesser, shall be provided.
(E) All subdivision plans will include the elevation of proposed structure(s) and lowest adjacent grade. If the site is filled above the base flood elevation, the lowest floor and lowest adjacent grade elevations shall be certified by a registered professional engineer or surveyor and provided to the Floodplain Administrator.
(Ord. 2008-03, passed 4-21-08)