838.107   RECIRCULATION SYSTEMS.
   The recirculation system shall meet all of the requirements specified in Section 838.33 except as specified below:
   (a)   The recirculation system for all pools at a waterpark facility, other than those specified in Section 838.33(b), shall be designed to accommodate the following required maximum turnover time:
      (1)   Children's Activity Pool, one hour.
      (2)   Wave pool, two hours.
      (3)   Receiving pool that is completely separate from the main body of the pool, has no more than two attractions, and has a volume of twenty thousand gallons or less shall be provided with a turnover time of one hour. The turnover time may be increased by one hour for every additional twenty thousand gallons of pool volume up to a maximum of four hours per turnover.
      (4)   All other pools, maximum of four hours.
(Ord. 07-14. Passed 12-18-07.)