SEC. 91.3003. EMERGENCY OPERATIONS.
   (Amended by Ord. No. 186,488, Eff. 12/27/19.)
 
   Section 3003 of the CBC is adopted by reference.
 
 
SEC. 91.3004. CONVEYING SYSTEMS.
   (Added by Ord. No. 184,692, Eff. 12/30/16.)
 
   CBC Section 3004 is adopted by reference, except CBC Section 3004.4 is not adopted.
 
 
SEC. 91.3005. CONVEYING SYSTEMS.
 
   Section 3005 of the CBC is adopted by reference, except that Section 3005.4 of the CBC is not adopted.
 
 
SEC. 91.3007. FIRE SERVICE ACCESS ELEVATOR.
   (Amended by Ord. No. 186,488, Eff. 12/27/19.)
 
   Section 3007 of the CBC is adopted by reference, except that Section 3007.1 of the CBC is not adopted; and, in lieu, LAMC Subsection 91.3007.1 is added.
 
91.3007.1. General. (Amended by Ord. No. 185,587, Eff. 7/16/18.) Where required by CBC Section 403.6.1, every floor of the building shall be served by fire service access elevators complying with CBC Sections 3007.1 through 3007.9 with the modifications set forth in this Code. Except as modified in this section, fire service access elevators shall be installed in accordance with this division and the Elevator Code.
 
 
SEC. 91.3008. OCCUPANT EVACUATION ELEVATORS.
   (Amended by Ord. No. 186,488, Eff. 12/27/19.)
 
   Section 3008 of the CBC is adopted by reference, except that Sections 3008.1 and 3008.1.1 of the CBC are not adopted; and, in lieu, LAMC Subsections 91.3008.1, 91.3008.1.1 and 91.3008.8.1 are added.
 
91.3008.1. General. Where elevators are to be used for occupant self-evacuation during fires, all passenger elevators for general public use shall comply with CBC Sections 3008.1 through 3008.10. Where other elevators are used for occupant self-evacuation, those elevators shall comply with these sections.
 
91.3008.1.1. Occupant evacuation elevators. Occupant evacuation elevators shall comply with the California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders.
 
91.3008.8.1. Determination of standby power load. Standby power loads shall be based on the determination of the number of occupant evacuation elevators in CBC Section 3008.1.
 
 
 
DIVISION 31
SPECIAL CONSTRUCTION
 
(Division Amended by Ord. No. 179,324, Eff. 12/10/07, Oper. 1/1/08.)
 
 
Section
91.3100   Basic Provisions.
91.3106   Marquees.
91.3108   Telecommunications and Broadcast Towers.
91.3109   Swimming Pool Enclosures and Safety Devices.
91.3112   Patio Covers.
 
 
SEC. 91.3100. BASIC PROVISIONS.
   Chapter 31 of the CBC is adopted by reference with the following exceptions, modifications and additions:
 
 