Skip to code content (skip section selection)
Compare to:
SEC. 94.400.0. BASIC PROVISIONS.
   (Amended by Ord. No. 187,719, Eff. 1/23/23.)
 
   Chapter 4 of the CPC is adopted by reference except CPC Sections 412.1 and 412.1.2 are not adopted, and LAMC Subsections 94.407.2.4, 94.412.1, 94.412.1.2, 94.414.4, and 94.414.5 are amended or added to read as follows:
 
94.407.2.4. All faucets in public restrooms shall be self-closing or self-closing metering faucets. Metered faucets shall deliver a maximum of 0.20 gallons (0.76 L) per metering cycle.
 
94.412.1. Application. Urinals shall comply with ASME A112.19.2/CSA B45.1, ASME A112.19.19, or CSA B45/IAPMO Z124. Wall-mounted urinals shall have an average water consumption not to exceed 0.125 gallons (0.47 L) per flush. Other urinals shall have an average water consumption not to exceed 0.125 gallons (0.47 L) per flush.
 
94.412.1.2. Floor-Mounted Urinals. [BSC-CG, DSA-SS, DSA-SS/CC]. The effective flush volume of floor-mounted or other urinals shall not exceed 0.125 gallons (0.47 L) per flush in compliance with Chapter 5, Division 5.3, of the California Green Buildings Standards Code (CAL Green).
 
94.414.4. Commercial Dishwashers. Water use for commercial dishwashers shall meet the following requirements:
 
 
Type
High-Temperature
Maximum Gallons Per Rack
Chemical
Maximum Gallons Per Rack
Conveyer
0.7
0.62
Door
0.95
1.16
Under-counter
0.9
0.98
Note: All installed dishwashers shall be Energy Star® rated
 
94.414.5. Domestic Dishwashers. The maximum water use per washing cycle for domestic dishwasher shall be 5.8 gallons (21.95L).