11-1-9: MOBILE HOME STANDARDS:
   A.   All mobile home parks and mobile home subdivisions located in an A zone shall file evacuation plans indicating vehicular access and escape routes, including mobile home hauler routes with appropriate disaster preparedness authorities.
   B.   All mobile homes to be placed on a site located in an A zone shall:
      1.   Have the lowest floor elevation one foot (1') above the base flood elevation.
      2.   In the instance of elevation on pilings, have all piling foundations placed in stable soil no more than ten feet (10') apart and reinforcement shall be provided for piers more than six feet (6') above ground.
      3.   Have lots large enough to permit steps to the mobile home and have adequate surface drainage on all sides of the structure.
      4.   Be placed to prevent flotation, collapse or lateral movement of the structure due to flooding.
      5.   Be anchored according to the following specifications:
         a.   Over the top ties shall be provided at each of the four (4) corners of the mobile home, with two (2) additional ties per side at intermediate locations and mobile homes less than fifty feet (50') long shall require one additional tie per side.
         b.   Frame ties shall be provided at each corner of the mobile home with five (5) additional ties per side at intermediate points and mobile homes less than fifty feet (50') long shall require four (4) additional ties per side.
         c.   All components of the anchoring system shall be capable of carrying four thousand eight hundred (4,800) pounds.
         d.   Any additions to the mobile home shall be similarly anchored. (Ord. 1114-83, 5-2-1983)