4-7-8: ELECTRICAL REQUIREMENTS:
   A.   Electrical Installations: All electrical installations provided for, installed and used in conjunction with private residential swimming pools shall be in conformance with chapter 5 of this title regulating electrical installations and NFPA 70 (2005) and to the extent the provisions of this chapter, chapter 5 of this title, and/or NFPA 70 (2005) are inconsistent, the more restrictive provisions shall govern and prevail.
   B.   Electrical Conductors: No current carrying electrical conductors shall cross private residential swimming pools, either overhead or underground or within fifteen feet (15') of such pools. No type MC cable shall be permitted in conjunction with swimming pools.
   C.   Metal Fences, Enclosures Or Railings: All metal fences, enclosures or railings near or adjacent to swimming pools, which might become electrically alive as a result of contact with broken overhead conductors or from any other cause, shall be effectively grounded.
   D.   Underwater Lighting Fixtures: Underwater lighting fixtures shall be approved for the service.
   E.   Location Of Receptacle: Where a permanently installed pool is installed at a dwelling unit(s), at least one GFCI protected one hundred twenty five (125) volt receptacle shall be located a minimum of ten feet (10') (3.05 m) from and not more than twenty feet (20') (6.10 m) from the inside wall of the pool.
   F.   Nuisances: Pools shall be operated with due consideration to the comfort and well being of adjoining property owners. Lighting shall be directed so as not to constitute a nuisance or annoyance to other property owners. (Ord. 06-822, 3-14-2006)