§ 52.095  NEW OR INCREASED DISCHARGES.
   All industrial user shall promptly notify the POTW in advance of any new or increased discharge. The town may deny or condition new or increased contributions of pollutants, or changes in the nature of pollutants, to the POTW by industrial users where such contributions do not meet applicable pretreatment standards and regulations or where such contributions would cause the POTW to violate its VPDES permit.
(1996 Code, § 168-37)
§ 52.096  REPORTS OF POTENTIAL PROBLEMS.
   (A)   In the case of any discharge including, but not limited to, accidental discharges, discharges of a non-routine, episodic nature, a non-customary batch discharge, or a slug load, that may cause potential problems for the POTW, the user shall immediately telephone and notify the Wastewater Superintendent of the incident. This notification shall include the location of discharge, type of waste, concentration and volume, if known, and corrective actions taken by the industrial user.
   (B)   Within five days following such discharge, the user shall, unless waived by the Wastewater Superintendent, submit a detailed written report describing the cause(s) of the discharge and the measures to be taken by the user to prevent similar future occurrences. Such notification shall not relieve the user of any expense, loss, damage or other liability which may be incurred as a result of damage to the POTW, natural resources or any other damage to person or property; nor shall such notification relieve the user of any fines, penalties or other liability which may be imposed pursuant to this chapter.
   (C)   A notice shall be permanently posted on the .user’s bulletin board or other prominent place advising employees whom to call in the event of a discharge described in division (A) above. Employers shall ensure that all employees, who may cause such a discharge to occur, are advised of the emergency notification procedure.
(1996 Code, § 168-38)
§ 52.097  REPORTS FROM PERMITTED USERS.
   All users not required to obtain a wastewater discharge permit shall provide appropriate reports to the Wastewater Superintendent as the Wastewater Superintendent may require.
(1996 Code, § 168-39)
§ 52.098  NOTICE OF VIOLATION/REPEAT SAMPLING AND REPORTING.
   If sampling performed by a user indicates a violation, the user must notify the Wastewater Superintendent within 24 hours of becoming aware of the violation. The user shall also repeat the sampling and analysis and submit the results of the repeat analysis to the Wastewater Superintendent within 30 days after becoming aware of the violation. The user is not required to resample if the POTW monitoring at the user’s facility at least once a month, or if the POTW samples between the user’s initial sampling and when the user receives the results of this sampling.
(1996 Code, § 168-40)
§ 52.099  NOTIFICATION OF THE DISCHARGE OF HAZARDOUS WASTE.
   (A)   The town reserves the right to refuse some or all discharges of hazardous waste.
   (B)   Any user who commences the discharge of hazardous waste shall notify the POTW, the EPA Regional Waste Management Division Director, and state hazardous waste authorities, in writing, of any discharge into the POTW of a substance which, if otherwise disposed of, would be a hazardous waste under 40 C.F.R. part 261. Such notification must include the name of the hazardous waste as set forth in 40 C.F.R. part 261, the EPA hazardous waste number, and the type of discharge (continuous, batch or other). If the user discharges more than 100 kilograms of such waste per calendar month to the POTW, the notification shall also contain the following information to the extent such information is known and readily available to the industrial user: an identification of the hazardous constituents contained in the wastes, an estimation of the mass and concentration of such constituents in the waste stream discharged during that calendar month, and an estimation of the mass of constituents in the waste stream expected to be discharged during the following 12 months. All notifications must take place no later than 180 days after the discharge commences. Any notification under this paragraph need be submitted only once for each hazardous waste discharged. However, notifications of changed discharges must be submitted under § 52.094. The notification requirement in this section does not apply to pollutants already reported by users subject to categorical pretreatment standards under the self-monitoring requirements of §§ 52.090 through 52.103.
   (C)   Dischargers are exempt from the requirements of division (A) above, during a calendar month in which they discharge no more than 15 kilograms of hazardous wastes, unless the wastes are acute hazardous wastes as specified in 40 C.F.R. §§ 261.30(d) and 261.33(e). Discharge of more than 15 kilograms of non-acute hazardous wastes in a calendar month, or of any quantity of acute hazardous wastes as specified in 40 C.F.R. §§ 261.30(d) and 261.33(e), requires a one-time notification. Subsequent months during which the user discharges more than such quantities of any hazardous waste do not require additional notification.
   (D)   In the case of any new regulations under § 3001 of RCRA identifying additional characteristics of hazardous waste or listing any additional substance as a hazardous waste, the user must notify the POTW, the EPA Regional Waste Management Waste Division Director, and state hazardous waste authorities of the discharge of such substance within 90 days of the effective date of such regulations.
   (E)   In the case of any notification made under this section, the user shall certify that it has a program in place to reduce the volume and toxicity of hazardous wastes generated to the degree it has determined to be economically practical.
   (F)   This provision does not create a right to discharge any substance not otherwise permitted to be discharged by this chapter, a permit issued thereunder, or any applicable federal or state law.
(1996 Code, § 168-41)
§ 52.100  ANALYTICAL REQUIREMENTS.
   All pollutant analyses, including sampling techniques, to be submitted as part of a wastewater discharge permit application or report shall be performed in accordance with the techniques prescribed in 40 C.F.R. part 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 C.F.R. part 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance with procedures approved by EPA.
(1996 Code, § 168-42)
§ 52.101  SAMPLE COLLECTION.
   (A)   Except as indicated in division (B) below, the user must collect wastewater samples using flow proportional composite collection techniques. In the event flow proportional sampling is infeasible, the Wastewater Superintendent may authorize the use of time proportional sampling or a minimum of four grab samples where the user demonstrates that this will provide a representative sample of the effluent being discharged. In addition, grab samples may be required to show compliance with instantaneous discharge limits.
   (B)   Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides and volatile organic chemicals must be obtained using grab collection techniques.
(1996 Code, § 168-43)