1329.06 MISCELLANEOUS REGULATIONS.
   (a)   Prefabricated fireplaces shall be installed as per the manufacturer's instructions and the provisions of Chapter 21 of the Ohio Residential Building Code provided that they comply with Section 1329.02 and that all portions of the chimney extending over the roofline shall be wrapped with stone, brick, or other approved material.
   (b)    No wood mantel or other woodwork shall be placed within eight (8") inches of the side or top of any fireplace openings.
   (c)    All fireplace chimneys shall have spark arresters installed over their flue openings.
   (d)    All fireplace hearths shall have a minimum on each side of eight (8") inches in width greater than the firebox and twenty (20") inches in depth from face of the firebox.