6-1-4   BUILDING CODE; AMENDMENTS.
   The following provisions shall further apply and shall supersede any and all references listed within the adopted edition of the International Building Code - 2003 Edition.
   (A)   Additions, Insertions and Changes.
      (1)   Section 101.1 - Insert “Village of Hecker”.
      (2)   Section 106.1.4 - Insert the following: Plans on Job Required: A set of the approved plans is required to be on the job site at the time of inspection.
      (3)   Insert Subsection 106.2.1:
      Section 106.2.1 - Compliance with Plot Plan. It shall be the responsibility of the builder/developer to submit to the Building Department a spot survey prepared by a Registered Land Surveyor after the foundation is installed. This survey must be at a scale of not less than one inch equal to thirty feet (1” = 30’). The survey must also indicate the elevation above sea level of the top of the foundation wall and the top of the curb and sidewalk at lot lines extended relative to a United States Geological Survey benchmark. No construction will be allowed to proceed except for decking, underground water and sewer, and related items until the spot survey is approved by the Building and Zoning Department. This
      Section applies to principal structures only and not to additions or accessory structures.
      (4)   Section 108.2 - Schedule of permit fees: Add the following: Building Permit fee schedule is found in Addendum “A” to this Chapter.
      (5)   Section 112 - Delete the section in its entirety and insert the following: The Village Board shall be the Board of Appeals.
      (6)   Section 113.4 - Violation Penalties: Insert the following: are hereby found in Section 1-1-20 of the Village Code.
      (7)   Section 501.2 - Premises identification add the following: The use of script address is not allowed.
      (8)   Section 501.2.1 - Add the following Tenant Identification: All buildings with multiple tenants or units shall have signs in the corridor across from the elevator door. This direction signage shall indicate the direction to each number tenant space. All tenant spaces shall have a sign, which indicates the tenant space number. The signs shall be constructed of durable materials, be permanently installed and be readily visible. Letters and numbers shall contrast with the background and shall be a minimum of 2 inches in height.
      (9)   Section 706.10: Add the following new section tenant separation: Each tenant shall be separated from other tenant spaces by fire barriers (walls and floor ceiling assemblies) having at least a one (1) hour fire rating.
      (10)   Section 901.6 - Change to read as follows: All water flow switches, valve supervision, trouble signals, fire alarm systems shall transmit an alarm to a location approved by the fire official.
      (11)   Add section 903.7 Sprinkler system design criteria. Sprinkler hydraulic designs for NFPA 13 and NFPA 13R systems shall be designed with a minimum of a five (5) pound difference between the sprinkler system design including hose requirements and the available water supply. The five (5) pound safety factor shall be applied to the water flow test after any adjustments for a seasonal low.
      (12)   Chapter 11 Insert the following text. When there is a conflict between this Chapter and the Illinois Accessibility Code the stricter of the two codes shall apply.
      (13)   Section 1612.3 Insert the Village of Hecker.
      (14)   Section 1512.3 Insert May 1, 2008.
      (15)   Sections 1805.0 Footings and Foundations all references to wood footings and foundations are deleted. The use of wood footings and foundations is prohibited.
      (16)   Section 2701.1 Delete the reference to the ICC Electric Code and insert the National Electric Code 2005 edition.
      (17)   Section 29-1.1 Delete references to the International Plumbing Code and add the following: The Village Building Official shall require that the provisions of the current “Illinois Plumbing Code Law”, 225 Illinois Compiled Statutes 320/1 et seq., as presently in force or as the same may be hereafter amended or modified and the same is hereby incorporated herein by reference and adopted as the standard for the purposes of this Chapter. Any conflicts concerning the provisions of these codes shall be determined by the strictest standard contained in the code provisions.
      (18)   Section 2902 Delete the section in its entirety.
      (19)   Sections 3410.2 Insert 2006.
      (20)   Reference Standards
      Delete the reference to the ICC Electric Code
      Delete the references to the International Plumbing Code in sections 101.4.4, 415.7.4, 717.5, 903.3.5, 1206.3.3, 2901.1, 2902.1, 3401.3 and insert the Illinois Plumbing Code.
      Adopt the following appendix.
         (a)   Appendix A - Employee qualifications
         (b)   Appendix C - Group U Agricultural Buildings
         (c)   Appendix D - Fire Districts
         (d)   Appendix F - Rodent proofing
         (e)   Appendix G - Flood Resistant Construction
         (f)   Appendix H - Signs
         (g)   Appendix I - Patio Covers
         (h)   Appendix J - Grading