§ 4-134  MINIMUM HOUSING REGULATIONS.
   (A)   Every mobile home located in either a mobile home park, a mobile home subdivision or as a freestanding mobile home, shall meet the provisions of the housing code of the city, except as otherwise provided in this section.
   (B)   Every mobile home shall contain the following minimum gross floor area or habitable space:
      (1)   One hundred-fifty square feet for one or two occupants;
      (2)   One hundred additional square feet for a third occupant; and
      (3)   Eighty square feet additional for each additional occupant thereafter.
   (C)   Habitable space in a mobile home shall have a minimum ceiling height of seven feet over 50 percent of the floor area and the floor area where the ceiling height is less than five feet shall not be considered in computing minimum gross floor area.
   (D)   A mobile home shall have a safe and unobstructed primary exit and an emergency exit located from the primary exit.
   (E)   Rooms occupied for sleeping purposes must contain at least 60 square feet of floor space if used by more than one person and at least 40 square feet if used by one person.
   (F)   Dependent mobile homes shall not be required to have flush toilet or a bath or shower.
   (G)   The housing code shall not apply to recreation vehicles insofar as floor area, flush toilet, bath or shower or ceiling height is concerned.
(`90 Code, § 4-62)  (Ord. 2767, passed 3-5-85)