SEC. 9-6-5 PROVISIONS FOR FLOOD HAZARD REDUCTION.
   (A)   General standards. In all special flood hazard areas the following provisions are required:
      (1)   All new construction and substantial improvement shall be anchored to prevent flotation, collapse or lateral movement of the structure;
      (2)   All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage;
      (3)   All new construction and substantial improvements shall be constructed by methods and practices that minimize flood damage;
      (4)   All new electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be elevated to the regulatory flood protection elevation and designed so as to prevent water from entering or accumulating within the components during conditions of flooding. These include but are not limited to HVAC equipment, water softener units, bath/kitchen fixtures, duct work, electric meter panels/boxes, utility/cable boxes, appliances (i.e., washers, dryers, refrigerator and the like), hot water heaters, electric outlets/switches;
         (a)   Replacements part of a substantial improvement, electrical, heating, ventilation, plumbing, air conditioning equipment, and other service equipment shall also meet the above provisions.
         (b)   Replacements that are for maintenance and not part of a substantial improvement, may be installed at the original location provided the addition and/or improvements only comply with the standards for new construction consistent with the code and requirements for the original structure.
      (5)   All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems;
      (6)   New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters;
      (7)   On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding;
      (8)   Nonconforming structures or other development may not be enlarged, replaced or rebuilt unless the enlargement or reconstruction is accomplished in conformance with the provisions of this chapter. Provided, however, nothing in this chapter shall prevent the repair, reconstruction or replacement of a building or structure existing on the effective date of this chapter and located totally or partially within the floodway, non-encroachment area, or stream setback provided that the bulk of the building or structure below regulatory flood protection elevation in the floodway, non-encroachment area, or stream setback is not increased and provided that such repair, reconstruction or replacement meets all of the other requirements of this chapter; and
      (9)   New solid waste disposal facilities, hazardous waste management facilities, salvage yards and chemical storage facilities shall not be permitted in special flood hazard areas. A structure or tank for chemical or fuel storage incidental to an allowed use or to the operation of a water treatment plant or wastewater treatment facility may be located in a special flood hazard area only if the structure or tank is either elevated or floodproofed to at least the regulatory flood protection elevation and certified according to section 9-6-4(B) of this chapter.
   (B)   Specific standards. In all special flood hazard areas where base flood elevation data have been provided as set forth in section 9-6-3(B) or section 9-6-4(E)(11) and (12), the following provisions are required:
      (1)   Residential construction. New construction or substantial improvement of any residential structure (including manufactured homes) shall have the reference level, including basement, elevated no lower than the regulatory flood protection elevation. Electrical, heating, ventilation, air-conditioning, plumbing, duct systems, and other equipment and service facilities shall be elevated at or above the RFPE, with the exception of electrical, heating, ventilation, plumbing, air conditioning equipment, and other service equipment that are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the design flood elevation.
(Ord. No. 00-19, § 4, passed 2-10-2000)
      (2)   Nonresidential construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure shall have the reference level, including basement, elevated no lower than the regulatory flood protection elevation. Structures located in Zones A, AE, AH, AO, A99 may be floodproofed to the regulatory flood protection elevation in lieu of being elevated, provided that all areas of the structure, together with attendant utility and sanitary facilities, below the required flood protection elevation are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. For AO Zones, the floodproofing elevation shall be in accordance with Section 9-6-5(G)(2). A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in section 9-6-4(B)(3) along with the operational plan and the inspection and maintenance plan.
      (3)   Manufactured homes.
         (a)   New or replacement manufactured homes shall be elevated on a foundation such that the reference level of the manufactured home is elevated no lower than the regulatory flood protection elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. For manufactured homes being used for residential purposes, electrical, heating, ventilation, air-conditioning, plumbing, duct systems, and other equipment and service facilities shall be elevated at or above the RFPE, with the exception of electrical, heating, ventilation, plumbing, air conditioning equipment, and other service equipment that are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the design flood elevation.
         (b)   Manufactured homes that are to be placed or substantially improved on sites in an existing manufactured home park or subdivision that are not subject to the provisions of subsection (B)(3)(a) above must be elevated so that the lowest floor of the manufactured home is elevated no lower than the regulatory flood protection elevation, and be securely anchored to an adequately anchored foundation to resist flotation, collapse and lateral movement in accordance with the State of North Carolina Regulations for Manufactured/Mobile Homes, 1995 Edition and any revision thereto adopted by the Commissioner of Insurance pursuant to G.S. 143-143.15 or a certified engineered foundation. Additionally, all manufactured homes located in special flood hazard areas must be installed either on a pre-approved foundation design from the Manual of Standard Designs and Details or on a foundation design certified by a professional engineer registered in the State of North Carolina. Furthermore, all tanks, decks, porches and steps to the manufactured home must be sufficiently designed and anchored to prevent collapse and/or flotation off the site, except that porches and steps serving a manufactured home on a lot that is less than five feet below the lowest floor of the manufactured home at the location of the porch or steps shall not be required to be anchored.
         (c)   An evacuation plan must be developed for evacuation of all residents of all new substantially improved or substantially damaged manufactured home parks or subdivisions located within flood prone areas. This plan shall be filed with and approved by the Local Floodplain Administrator and the local Emergency Management Coordinator.
         (d)   When the elevation of the manufactured home would be met by an elevation of the chassis 36 inches or less above the grade at the site, the chassis shall be supported by reinforced piers or other foundation elements of at least equivalent strength.
         (e)   If a manufactured home is placed with the elevation of the chassis above 36 inches in height, an engineered foundation certification is required per subsection (B)(3).
         (f)   All foundation enclosures or skirting shall be in accordance with subsection (B)(5) of this section.
      (4)   Recreational vehicles. Recreational vehicles placed on sites within a special flood hazard area shall either:
         (a)   Be on site for fewer than 180 consecutive days;
         (b)   Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick- disconnect type utilities and has no permanently attached additions); or
         (c)   Meet all the requirements for new construction, including anchoring and elevation requirements of section 9-6-4(B) and subsections (A) and (B)(3) of this section.
      (5)   Elevated buildings. New construction or substantial improvements of elevated buildings that include fully enclosed areas that are below the regulatory flood protection elevation shall not be designed for human habitation, but shall be designed to be usable solely for the parking of vehicles, building access or limited storage of maintenance equipment used in connection with the premises in an area other than a basement, be constructed entirely of flood resistant materials below the regulatory flood protection level and meet the following design criteria.
          (a)   Measures for complying with this requirement shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. To meet this requirement, the foundation must either be certified by a professional engineer or architect or meet the following minimum criteria:
            1.   Provide a minimum of two openings on different sides of each enclosed area subject to flooding having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding;
            2.   The bottom of all openings shall be no higher than one foot above the adjacent grade;
            3.   Openings may be equipped with screens, louvers or other coverings or devices, provided they permit the automatic flow of floodwaters in both directions;
            4.   If a building has more than one enclosed area, each area must have openings on exterior walls to allow floodwater to directly enter; and
            5.   Foundation enclosures:
               a.   Vinyl or sheet metal skirting is not considered an enclosure for regulatory and flood insurance rating purposes. Therefore such skirting does not require hydrostatic openings as outlined above.
               b.   Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires hydrostatic openings as outlined above to comply with this chapter.
         (b)   Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and
         (c)   The interior portion of the enclosed area shall not be partitioned or finished into separate rooms except to enclose storage areas.
         (d)   Where the lowest floor is more than four feet high, property owners shall be required to execute and record a non-conversion agreement prior to issuance of a building permit declaring that the area below the lowest floor shall not be improved, finished or otherwise converted to habitable space and the Floodplain Administrator shall have the right to inspect the enclosed area. This agreement shall be recorded with the Pitt County Register of Deeds and shall transfer with the property in perpetuity.
         (e)   Release of restrictive covenant. If a property which is bound by a nonconversion agreement is modified to remove enclosed areas below the regulatory flood elevation, then the owner may request release of restrictive covenant after staff inspection and submittal of confirming documentation.
      (6)   Temporary structures. Prior to the issuance of a floodplain development permit for a temporary structure, the following requirements must be met:
         (a)   All applicants must submit to the Local Floodplain Administrator prior to the issuance of the floodplain development permit a plan for the removal of the structure(s) in the event of a hurricane or flash flood warning notification. The plan must include the following information:
            1.   A specific time period for which the temporary use will be permitted:
            2.   The name, address and phone number of the individual responsible for the removal of the temporary structure;
            3.   The time frame prior to the event at which a structure will be removed (i.e., minimum of 72 hours before landfall of a hurricane or immediately upon flood warning notification);
            4.   A copy of the contract or other suitable instrument with a trucking company to ensure the availability of removal equipment when needed; and
            5.   Designation, accompanied by documentation, of a location outside the floodplain to which the temporary structure will be moved.
         (b)   The above information shall be submitted in writing to the Local Administrator for review and written approval.
      (7)   Accessory structures. When accessory structures (sheds, detached garages and the like) are to be placed in the floodplain, the following criteria shall be met:
         (a)   Accessory structures shall not be used for human habitation (including work, sleeping, living, cooking or restroom areas);
         (b)   Accessory structures shall be designed to have low flood damage potential;
         (c)   Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistant to the flow of flood waters;
         (d)   Accessory structures shall be firmly anchored in accordance with subsection (A)(1) above;
         (e)   All service facilities such as electrical and heating equipment shall be elevated in accordance with subsection (A)(4) above; and
            1.    Openings to relieve hydrostatic pressure during a flood shall be provided below regulatory flood protection elevation in conformance with subsection (B)(5).
            2.    An accessory structure with a footprint less than 150 square feet does not require an elevation or floodproofing certificate. Elevation or floodproofing certifications are required for all other accessory structures in accordance with section 9-6-4(B).
      (8)   Additions/improvements.
         (a)   Additions and/or improvements to pre-FIRM structures whereas the addition and/or improvements in combination with any interior modifications to the existing structure:
             1.   Are not a substantial improvement, the addition and/or improvements must be designed to minimize flood damages and must not be any more nonconforming than the existing structure;
            2.   Are a substantial improvement, both the existing structure and the addition and/or improvements must comply with the standards for new construction.
         (b)   Additions to post-FIRM structures with no modifications to the existing structure shall require only the addition to comply with the standards for new construction.
         (c)   Additions and/or improvements to post-FIRM structures whereas the addition and/or improvements in combination with any interior modifications to the existing structure:
            1.   Are not a substantial improvement, the addition and/or improvements only must comply with the standards for new construction;
            2.   Are a substantial improvement, both the existing structure and the addition and/or improvements must comply with the standards for new construction.
         (d)   Where a fire wall or independent perimeter load-bearing wall is provided between the addition and the existing building, the addition(s) shall be considered a separate building and only the addition must comply with the standards for new construction.
         (e)   Any combination of repair, reconstruction, rehabilitation, addition or improvement of a building or structure taking place during a one-year period, the cumulative cost of which equals or exceeds 49% of the market value of the structure before the improvement or repair is started must comply with the standards for new construction. For each building or structure, the one-year period begins on the date of the first improvement or repair of that building or structure subsequent to the date of this ordinance. Substantial damage also means floodrelated damage sustained by a structure on two separate occasions during a ten-year period for which the cost of repairs at the time of each such flood event, on the average, equals or exceeds 25% of the market value of the structure before the damage occurred. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The requirement does not, however, include either:
            l.   Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assume safe living conditions.
            2.   Any alteration of a historic structure provided that the alteration will not preclude the structure's continued designation as a historic structure.
      (9)   Tanks. When gas and liquid storage tanks are to be placed within a Special Flood Hazard Area, the following criteria shall be met:
         (a)   Underground tanks. Underground tanks in flood hazard areas shall be anchored to prevent flotation, collapse or lateral movement resulting from hydrodynamic and hydrostatic loads during conditions of the design flood, including the effects of buoyancy assuming the tank is empty;
         (b)   Above-ground tanks, elevated. Above-ground tanks in flood hazard areas shall be elevated to or above the Regulatory Flood Protection Elevation on a supporting structure that is designed to prevent flotation, collapse or lateral movement during conditions of the design flood. Tank-supporting structures shall meet the foundation requirements of the applicable flood hazard area;
         (c)   Above-ground tanks, not elevated. Above-ground tanks that do not meet the elevation requirements of section 9-6-5 (B)(2) of this ordinance shall be permitted in flood hazard areas provided the tanks are designed, constructed, installed, and anchored to resist all flood-related and other loads, including the effects of buoyancy, during conditions of the design flood and without release of contents in the floodwaters or infiltration by floodwaters into the tanks. Tanks shall be designed, constructed, installed, and anchored to resist the potential buoyant and other flood forces acting on an empty tank during design flood conditions.
         (d)   Tank inlets and vents. Tank inlets, fill openings, outlets and vents shall be:
            1.   At or above the Regulatory Flood Protection Elevation or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the design flood; and
            2.   Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the design flood.
      (10)   Other development.
         (a)   Fences in regulated floodways and NEAs that have the potential to block the passage of floodwaters, such as stockade fences and wire mesh fences, shall meet the limitations of section 9-6-5(C) of this ordinance.
         (b)   Retaining walls, sidewalks and driveways in regulated floodways and NEAs. Retaining walls and sidewalks and driveways that involve the placement of fill in regulated floodways shall meet the limitations of section 9-6-5(C) of this ordinance.
         (c)   Roads and watercourse crossings in regulated floodways and NEAs. Roads and watercourse crossings, including roads, bridges, culverts, lowwater crossings and similar means for vehicles or pedestrians to travel from one side of a watercourse to the other side, that encroach into regulated floodways shall meet the limitations of section 9-6-5(C) of this ordinance.
   (C)   Floodways and non-encroachment areas. Located within special flood hazard areas established in section 9-6-3(B) are areas designated as floodways or non-encroachment areas. Since the floodways and non-encroachment areas are extremely hazardous areas due to the velocity of flood waters which carry debris, potential projectiles and have erosion potential, the following provisions shall apply to all development within such areas:
      (1)   No encroachments, including fill, new construction, substantial improvements and other developments shall be permitted unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels during occurrence of the base flood. Such certification and technical data shall be presented to the Local Floodplain Administrator.
      (2)   If subsection (C)(1) is satisfied, all development and substantial improvements shall comply with all applicable flood hazard reduction provisions of this chapter.
      (3)   No manufactured homes shall be permitted, except replacement manufactured homes in an existing manufactured homes (mobile homes) park or subdivision, provided the anchoring and the elevation standards of subsection (B)(3), and the non-encroachment standards of subsection (B)(1) are met.
      (4)   Notwithstanding any other provisions of 44 C.F.R. § 60.3, a community may permit encroachments within the adopted regulatory floodway or non-encroachment area that would result in an increase in base flood elevations, provided that the community first applies for a conditional LOMR and floodway revision, fulfills the requirements for such revisions as established under the provisions of 44 C.F.R. § 65.12 of the “National Flood Insurance Program and Related Regulations,” and receives the approval of the Local Floodplain Administrator prior to commencement of the development.
   (D)   Standards for floodplains without established base flood elevations. Within the special flood hazard areas established in section 9-6-3(B) are floodplains where no base flood elevation data has been provided, the following provisions shall apply:
      (1)   No encroachments, including fill, new construction, substantial improvements or new development shall be permitted within a distance of the stream bank equal to five times the width of the stream at the top of bank or 20 feet each side from top of bank, whichever is greater, unless certification with supporting technical data by a registered professional engineer is provided demonstrating that the encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge.
      (2)   If subsection (E)(1) is satisfied and base flood elevation is available from other source, all new construction and substantial improvements within such areas shall comply with all applicable provisions of this chapter and shall be elevated or floodproofed in accordance with elevations established in accordance with section 9-6-4(E)(11) and (12). When base flood elevation data is not available from a federal, state or other source, the reference level, including basement, shall be elevated at least two feet above the highest adjacent grade.
   (E)   Standards for subdivision, manufactured home park and major development proposals.
      (1)   All proposals shall be consistent with the need to minimize flood damage;
      (2)   All proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage;
      (3)   All proposals shall have adequate drainage provided to reduce exposure to flood hazards; and
      (4)   Base flood elevation data shall be provided for all proposals and other proposed development, which is greater than the lesser of 50 lots/manufactured home sites or five acres. Such base flood elevation (BFE) data shall be adopted by reference per section 9-6-3(B) to be utilized in implementing this Code.
   (F)   Standards for floodplains with BFE but without established floodways or non-encroachment areas. Along rivers and streams where base flood elevation (BFE) data is provided but neither floodway nor non-encroachment areas are identified for a special flood hazard area on the FIRM or in the FIS, no encroachments, including fill, new construction, substantial improvements, or other development, shall be permitted unless certification with supporting technical data by a registered professional engineer is provided, demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community.
   (G)   Standards for areas of shallow flooding (AH Zones). Located within the special flood hazard areas established in section 9-6-3(B) are areas designated as shallow flooding areas. These areas have special flood hazards associated with base flood depths of one to three feet where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate. The following provisions apply within such areas:
      (1)   All new construction and substantial improvements of all structures shall have the lowest floor, including basement, elevated to the depth number specified on the Flood Insurance Rate Map, in feet, above the highest adjacent grade. If no depth number is specified, the lowest floor, including basement, shall be elevated at least to the regulatory flood protection elevation as defined for the special flood hazard areas where no BFE has been established.
      (2)   All new construction and substantial improvements of nonresidential structures shall have the option, in lieu of elevation, to be completely floodproofed together with attendant utilities and sanitary facilities to or above that level so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Certification is required as per section 9-6-4(B)(3) and section 9-6-4(B)(2).
(Ord. No. 03-123, passed 12-15-2003; Ord. No. 20-022, passed 5-18-2020; Ord. No. 22-056, passed 6-9-2022)