15-8   Wiring In Single And Multiple-Family Units
   A.   Multiple family units may have branch circuits in individual units wired with nonmetallic sheathed cable if construction complies with Chapter 8 of the Grand Island City Code.
   B.   Existing residential buildings containing more than six family units not having a two-hour fire wall rating separation as provided in Chapter 8 of the Grand Island City Code shall not be wired with nonmetallic cable.
   C.   No wiring in basements below the floor joist on exterior walls shall be wired with unprotected nonmetallic cable.
   D.   Smoke alarms shall be installed to comply with Section R314 of the 2021 International Residential Code.
   E.   Carbon monoxide alarms shall be installed to comply with Section R315 of the 2021 International Residential Code.