8-16   IRC - Amendment Of Table R301.2(1) And Table 301.5
Section R301.2 of the International Residential Code is hereby amended by adding criteria as set forth in Table R301.2(1). Ground snow load – 25#
Wind Speed – Ultimate Design Wind Speed 114 mph Seismic Design Category A, Site Class D. Weathering --sever
Frost line Depth --36” Termite -- M/H
Ice Barrier Underlayment Required – NO Flood Hazard – Firm
Air Freezing Index -- >1000-2000 Mean Annual Temp – 49.9 F
Amend Table R301.5 Minimum Uniform Distributed Live Loads – Sleeping Rooms – 40#
(Amended by Ordinance No. 8955, effective 03-31-2005) (Amended by Ordinance No. 9162, effective 05-01-2008) (Amended by Ordinance No. 9365, effective 03-30-2012) (Amended by Ordinance No. 9475, effective 04-15-2014) (Amended by Ordinance No. 9661, effective 01-01-2018)
HISTORY
Amended by Ord. 9958 on 12/20/2023