9-6-31: WATER SUPPLY AND DISTRIBUTION SYSTEM:
   A.   General Requirements: An accessible, adequate, safe and potable supply of water shall be provided in each mobile home development. Where a public supply of water of satisfactory quantity, quality and pressure is available at the site or at the boundary of the site, connection shall be made thereto and its supply used exclusively. When a satisfactory public water supply is not available, a private water supply system may be developed and used as approved by the health authority.
   B.   Water Distribution System:
      1.   Public distribution systems intended to be operated and maintained by the enforcing agency shall be constructed in accordance with standards and specifications of the enforcing agency.
      2.   Private distribution systems intended to be operated and maintained by the mobile home community management shall be constructed in accordance with the standards and specifications of the health authority.
      3.   Fire hydrants shall be located within two hundred fifty feet (250') of any mobile home, service building or other structure in the development.
   C.   Individual Water Riser Pipes And Connections:
      1.   Individual water riser pipes shall be located within the area of the mobile home stand and approximately thirty feet (30') from the front of such stand.
      2.   Water riser pipes shall extend at least four inches (4") above ground elevation. The pipe diameter shall be at least three- fourths inch (3/4"). The water outlet shall be capped when a mobile home does not occupy the lot.
      3.   Adequate provisions shall be made to prevent freezing of service lines, valves and riser pipes and to protect risers from heaving and thawing actions of ground during freezing weather. Surface drainage shall be diverted from the location of the riser pipe.
      4.   A shutoff valve below the frost line shall be provided near the water riser pipe on each mobile home lot. (Ord. 84-9)