15.36.080 Service building and accommodation requirements.
   A.   Every trailer court shall have erected thereon, at a distance not greater than two hundred feet from any unit it is designed to serve, a suitable building for housing toilets, showers and laundry facilities, as required by this chapter. Such buildings shall be well lighted at all times, day or night, well ventilated with screened openings, and constructed of such moisture proof material as shall permit rapid and satisfactory cleaning, scouring and washing.
   B.   There shall be provided separate toilet rooms for each sex. Flush toilets provided with an adequate water supply shall be enclosed in separate compartments and shall be provided for each sex in the ratio of one toilet for each ten units or major fraction thereof. Every male toilet room shall have one urinal for each twenty units, but in no case shall any male toilet room be without one urinal. Toilet rooms shall contain lavatories with hot and cold water in the ratio of one lavatory to every four or less water closets.
   C.   Separate bathing facilities for each sex shall be provided with one shower enclosed in a compartment for each ten units or major fraction thereof.
   D.   Laundry facilities shall be provided in the ratio of one double tray for each fifteen units, or major fraction thereof.
   E.   The above accommodations shall be based on the total court capacity according to the accepted plans, provided that in the event trailers occupying a trailer court are equipped with toilet, bathing and laundry facilities, such facilities need not be erected for trailers so equipped, and provided further, that it shall be unlawful to rent trailer space to trailers not so equipped unless such facilities shall have been erected in ratios provided for in subsections A, B and D of this section. If the operator of a trailer court adopts, files with the city and enforces a written rule for the trailer court requiring each trailer parked in his trailer court to have an independent toilet facility, the provisions of subsection B of this section shall not apply except that each trailer court shall have at least one central toilet facility for each sex. If the operator of a trailer court adopts, files with the city and enforces a written rule for the trailer court requiring each trailer parked in his trailer court to have an independent bathing facility, the provisions of subsection C of this section shall not apply.
   F.   The floors of toilets, showers, and the laundry shall be of concrete, tile or similar material, impervious to water, and easily cleaned and pitched to a floor drain.
(Prior code § 16-2-5)