1107.04 BUFFERING REQUIREMENTS.
   The following table identifies the buffering requirements required between land uses of varying intensities.
TABLE 1107.04-1: BUFFERING REQUIREMENTS
 
When.....
Is Proposed to Abut......
A minimum Buffering of.......
Any multifamily dwelling use, non-residential use (including industrial), or mixed use development
A single-family dwelling (attached or attached), or two-family use
10 feet wide side or rear yard that consists of one of the following:
(1)   1 deciduous tree planted every 30 lineal feet
+ a continuous row of minimum 6 feet high evergreen plantings;
(2)   6 feet wall or opaque fence + 1 deciduous tree planted every 30 lineal feet;
(3)   A double row, staggered planting of minimum 6 feet high evergreen trees planted every 15 lineal feet; or
(4)   A 40 feet wide, 6 feet tall earthen berm with deciduous trees planted every 30 lineal feet
Any industrial use
Commercial, public, or institutional use
Any off-street parking lot for any multifamily dwelling use, non- residential use, or mixed
use development
The public right-of-way, public or private street, single-family dwelling (attached or detached),
or two-family use
10 foot wide buffer that consists of 1 deciduous tree every 30 feet and shrubs planted every 3 lineal feet that are a minimum of 24 inches in height at the time of planting (1 tree minimum is required)
(Ord. 2022-34. Passed 1-9-23.)