1104.04 INDUSTRIAL DISTRICT DIMENSIONAL STANDARDS.
   The following table identifies the specific development standards that apply to each of the industrial zoning districts.
TABLE 1104.04-1: INDUSTRIAL DISTRICT DIMENSIONAL STANDARDS
L-I
G-I
Minimum Front Yard Setback 2
50 feet
50 feet
Minimum Side Yard Setback 2
20 feet (40 feet if adjacent to
residential)
20 feet (40 feet if adjacent to
residential)
Minimum Rear Yard Setback 2
20 feet (40 feet if adjacent to
residential)
20 feet (40 feet if adjacent to
residential)
Minimum Lot Width
125 feet
125 feet
Minimum Lot Area
1 acre
1 acre
Minimum Open Space
20%
20%
Maximum Height 1
42 feet
42 feet
Minimum Accessory Structure Setbacks
Same as principal building
Same as principal building
Maximum Accessory Structure Height
20 feet
20 feet
Minimum Parking Front Yard Setback
20 feet
20 feet
Minimum Parking Side Yard Setback
10 feet (20 feet if adjacent to residential)
10 feet (20 feet if adjacent to residential)
Minimum Parking Rear Yard Setback
10 feet (20 feet if adjacent to residential)
10 feet (20 feet if adjacent to residential)
   (a)   Building Height Regulations. In the L-I and G-I Zoning Districts, any building that exceeds thirty (30) feet is required to provide an additional one (1) foot of side and rear yard setbacks for every foot of building height that exceeds thirty (30) feet. Height exceptions for architectural projections are regulated in Section 1104.06(b).
   (b)   Yard Requirement Exceptions. Yard requirements may be reduced, if approved by Planning Commission, where on-site circulation, parking, and loading are coordinated with adjoining developments and set forth in a joint agreement.
      (Ord. 2022-34. Passed 1-9-23.)