(A) Construction plans for the following improvements shall be furnished in accordance with the specifications of the officials having jurisdiction and shall receive approval of those officials before the improvements are installed.
(1) The center line profile (and natural profile) of each proposed street at a scale represented by not more than 50 feet to the inch, with tentative grades indicated.
(2) Cross section of each proposed street, at not more than each 50-foot station, showing the width of pavements, and the locations and widths of sidewalks.
(3) The plans and profiles of proposed sanitary sewers, with grades and sizes indicated. The elevation of the sanitary sewer house service shall be indicated at the lot line.
(4) A plan and profile of the proposed water distribution system, showing the pipe sizes and the location of valves and fire hydrants.
(5) A plan and profile of the proposed storm sewer system, showing the pipe sizes and the locations of catch basins and inlets.
(B) Construction standards and material specifications for streets and street drainage shall be those currently in force by the city.
(C) Permanent monuments shall be placed in accordance with the requirements of the city engineer.
(1980 Code, § 151.47) (Ord. 3704, passed 6-5-1978)