1705.02  AMENDMENTS.
   The Village of Barboursville/State Building Code is hereby amended with the following insertions:
   (a)   2012 International Building Code
      Section 101.1 insert: The Village of Barboursville
      (1)   Section 1612.3 insert: Village of Barboursville .... February 19, 2014
      (2)   The Village of Barboursville hereby adopts the following IBC 2012
         Appendices:
            Appendix C - Group U Agricultural Buildings
            Appendix E - Supplementary Accessibility Requirements
            Appendix F - Rodent Proofing
            Appendix G - Flood-resistant construction
            Appendix H- Signs
            Appendix I - Patio Covers
            Appendix J- Grading
   (b)    2009 International Residential Code
      Section R 101.1 insert: Village of Barboursville
      Table R301.2 (1) insert: Ground Snow Load-= or> than 20 psf live load
         Wind speed - 90 mph
         Seismic Design Category - B
         Weathering - Severe
         Frost Line Depth - 24"
         Termite - M-H
         Decay - S-M
         Winter Design Temp - 10 degrees
         Ice Shield Underlayment Required - Yes
         Flood Hazards - June 16, 2005
         Air Freezing Index - 500
         Mean Annual Temp - 50.4
Section P2603.3.6.1 insert: 24 inches for building sewers that connect to private sewage disposal systems; insert 24 inches for building sewers below grade;
Section P3103.1 delete six inches and insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
The Village of Barboursville hereby adopts the following Appendices to the IRC 2009:
      Appendix E - Manufactured Housing used as Dwellings
      Appendix G - Swimming Pools, Spas and Hot Tubs
      Appendix H- Patio Covers
      Appendix J- Existing Building and Structures
      Appendix K- Sound Transmissions
   (c)   2012 International Existing Building Code
      Section 101.1 insert: Village of Barboursville
      Section 1301.3 insert: January 1, 1989
The Village of Barboursville hereby adopts the following Appendices to the IEBC 2012:
Appendix B - Supplementary Accessibility Requirements for Existing Building and Facilities
   (d)   2012 International Plumbing Code
      Section 101.1 insert: Village of Barboursville
Section 305.6 insert: 24 inches private sewage disposal .... 24 inches building sewers
Section 904.1 insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
The Village of Barboursville hereby adopts the following Appendices to IPC 2012
      Appendix D- Degree Day and Design Temp (Charleston)
      Appendix E -Sizing of Pipe Systems
      Appendix F- Structural Safety
      Appendix G -Vacuum Drainage System
   (e)   2012 International Mechanical Code
Section 101.1 insert: Village of Barboursville
The Village of Barboursville hereby adopts the following Appendix to the IMC 2012:
      Appendix A- Combustion Air Openings and Chimney Pass-Through
   (f)   2012 International Fuel Gas Code
      Section 101.1 insert: Village of Barboursville
The Village of Barboursville hereby adopts the following Appendices to IFGC 2012:
      Appendix A- Sizing and Capacities of Gas Piping
      Appendix B- Sizing of Vent Systems
Appendix C- Exit Terminals of Mechanical Draft Systems and Direct Vent Venting System
   (g)   2009 International Energy Conservation Code -for residential buildings, effective 11/30/13
      Section 101.1 insert: Village of Barboursville
   (h)   2012 International Property Maintenance Code
      Section 101.1 insert: Village of Barboursville
      Section 302.4 insert: 10 inches
      Section 304.14 insert: April 15 to November 15
      Section 602.3 insert: November 15 to April 30
      Section 602.4 insert: November 15 to April 30
      (Ord. 2014-05.  Passed 6-3-14.)