The Village of Barboursville/State Building Code is hereby amended with the following insertions:
(a) 2018 International Building Code
Section 101.1 insert: The Village of Barboursville
(b) Section 1612.3 insert: Village of Barboursville .... August 1, 2022
(c) The Village of Barboursville hereby adopts the following IBC 2018 Appendices:
Appendix C - Group U Agricultural Buildings
Appendix E - Supplementary Accessibility Requirements
Appendix F - Rodent Proofing
Appendix G - Flood-resistant construction
Appendix H - Signs
Appendix I - Patio Covers Appendix J - Grading
(d) 2018 International Residential Code
Section R101.1 insert: Village of Barboursville
Table R301.2 (1) insert: Ground Snow Load - = or> than 20 psf live load
Wind speed - 90 mph Seismic Design Category - B
Weathering - Severe
Frost Line Depth - 24" Termite - M-H Decay- S-M
Winter Design Temp - 10 degrees
Ice Shield Underlayment Required - Yes Flood Hazards - June 16, 2005
Air Freezing Index - 500 Mean Annual Temp - 50.4
Section P2603.3.6.1 insert: 24 inches for building sewers that connect to private sewage disposal systems; insert 24 inches for building sewers below grade;
Section P3103.1 delete six inches and insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
The Village of Barboursville hereby adopts the following Appendices to the IRC 2018:
Appendix E - Manufactured Housing used as Dwellings
Appendix G - Swimming Pools, Spas and Hot Tubs
Appendix H - Patio Covers
Appendix J- Existing Building and Structures
Appendix K - Sound Transmissions
(e) 2018 International Existing Building Code Section
101.1 insert: Village of Barboursville Section 1301.3
insert: January 1, 1989
The Village of Barboursville hereby adopts the following Appendices to the IEBC 2018:
Appendix B - Supplementary Accessibility Requirements for Existing Building and Facilities
(f) 2018 International Plumbing Code
Section 101.1 insert: Village of Barboursville
Section 305.6 insert: 24 inches private sewage disposal ..................... 24 inches
building sewers
Section 904.1 insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
The Village of Barboursville hereby adopts the following Appendices to IPC 2012
Appendix D - Degree Day and Design Temp (Charleston)
Appendix E - Sizing of Pipe Systems
Appendix F - Structural Safety
Appendix G - Vacuum Drainage System
(g) 2018 International Mechanical Code
Section 101.1 insert: Village of Barboursville
The Village of Barboursville hereby adopts the following Appendix to the IMC 2018:
Appendix A - Combustion Air Openings and Chimney Pass-Through
(h) 2018 International Fuel Gas Code
Section 101.1 insert: Village of Barboursville
The Village of Barboursville hereby adopts the following Appendices to IFGC 2012:
Appendix A - Sizing and Capacities of Gas Piping
Appendix B - Sizing of Vent Systems
Appendix C - Exit Terminals of Mechanical Draft Systems and Direct Vent Venting System
(i) 2015 International Energy Conservation Code - for residential buildings
Section 101.1 insert: Village of Barboursville
(j) 2018 International Property Maintenance Code
Section 101.1 insert: Village of Barboursville
Section 302.4 insert: 10 inches
Section 304.14 insert: April 15 to November 15
Section 602.3 insert: November 15 to April 30
Section 602.4 insert: November 15 to April 30
(Ord. 2022-06. Passed 7-19-22.)