1705.02 STATE BUILDING CODE - AMENDMENTS.
   The Village of Barboursville/State Building Code is hereby amended with the following insertions:
   (a)   2018 International Building Code
      Section 101.1 insert: The Village of Barboursville
   (b)   Section 1612.3 insert: Village of Barboursville .... August 1, 2022
   (c)   The Village of Barboursville hereby adopts the following IBC 2018 Appendices:
      Appendix C - Group U Agricultural Buildings
      Appendix E - Supplementary Accessibility Requirements
      Appendix F - Rodent Proofing
      Appendix G - Flood-resistant construction
      Appendix H - Signs
      Appendix I - Patio Covers Appendix J - Grading
   (d)   2018 International Residential Code
      Section R101.1 insert: Village of Barboursville
      Table R301.2 (1) insert: Ground Snow Load - = or> than 20 psf live load
         Wind speed - 90 mph Seismic Design Category - B
         Weathering - Severe
         Frost Line Depth - 24" Termite - M-H Decay- S-M
         Winter Design Temp - 10 degrees
         Ice Shield Underlayment Required - Yes Flood Hazards - June 16, 2005
         Air Freezing Index - 500 Mean Annual Temp - 50.4
Section P2603.3.6.1 insert: 24 inches for building sewers that connect to private sewage disposal systems; insert 24 inches for building sewers below grade;
Section P3103.1 delete six inches and insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
      The Village of Barboursville hereby adopts the following Appendices to the IRC 2018:
      Appendix E - Manufactured Housing used as Dwellings
      Appendix G - Swimming Pools, Spas and Hot Tubs
      Appendix H - Patio Covers
      Appendix J- Existing Building and Structures
      Appendix K - Sound Transmissions
   (e)   2018 International Existing Building Code Section
      101.1 insert: Village of Barboursville Section 1301.3
      insert: January 1, 1989
      The Village of Barboursville hereby adopts the following Appendices to the IEBC 2018:
Appendix B - Supplementary Accessibility Requirements for Existing Building and Facilities
   (f)   2018 International Plumbing Code
      Section 101.1 insert: Village of Barboursville
      Section 305.6 insert: 24 inches private sewage disposal ..................... 24 inches
                                 building sewers
      Section 904.1 insert: at least 12 inches above the roof or 12 inches above the anticipated snow accumulation
The Village of Barboursville hereby adopts the following Appendices to IPC 2012
Appendix D - Degree Day and Design Temp (Charleston)
      Appendix E - Sizing of Pipe Systems
      Appendix F - Structural Safety
      Appendix G - Vacuum Drainage System
   (g)   2018 International Mechanical Code
      Section 101.1 insert: Village of Barboursville
       The Village of Barboursville hereby adopts the following Appendix to the IMC 2018:
      Appendix A - Combustion Air Openings and Chimney Pass-Through
   (h)   2018 International Fuel Gas Code
      Section 101.1 insert: Village of Barboursville
The Village of Barboursville hereby adopts the following Appendices to IFGC 2012:
      Appendix A - Sizing and Capacities of Gas Piping
      Appendix B - Sizing of Vent Systems
      Appendix C - Exit Terminals of Mechanical Draft Systems and Direct Vent Venting System
   (i)   2015 International Energy Conservation Code - for residential buildings
      Section 101.1 insert: Village of Barboursville
   (j)   2018 International Property Maintenance Code
      Section 101.1 insert: Village of Barboursville
      Section 302.4 insert: 10 inches
      Section 304.14 insert: April 15 to November 15
      Section 602.3 insert: November 15 to April 30
      Section 602.4 insert: November 15 to April 30
      (Ord. 2022-06. Passed 7-19-22.)