§ 24-177. SPECIFIC STANDARDS.
   In all areas of special flood hazards where base flood elevation data has been provided as set forth in §§ 24-25, 24-56(B)(8), and 24-178, the following provisions are required.
   (A)   Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to or above the base floor elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection (A), as proposed in § 24-87(A)(1), is satisfied.
   (B)   Nonresidential construction. New construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement) elevated to above the flood level, or, together with attendant utility and sanitary facilities, be designed so that below the base flood level, the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this section. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the floodplain administrator.
   (C)   Manufactured homes.
      (1)   All manufactured homes to be placed within zone A shall be installed using methods and practices which minimize flood damage. For the purpose of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state or local anchoring requirements for resisting wind forces.
      (2)   All manufactured homes shall be in compliance with subsection (A) above of this section.
(Prior Code, § 24-177) (Ord. 780, passed 1-18-1988)