1167.05 SUPPORT STRUCTURES.
   (a)   Only metal support, galvanized construction or equal thereto, shall be allowed.
   (b)   Only a concrete base or caissons, depending on soil conditions, shall be employed in line with grade.
   (c)   The structure shall be designed to withstand wind force of up to eighty-five miles per hour in a manner conforming with good engineering practices.
   (d)   Any driving motor shall be limited to 120 volts maximum power design and shall be encased in protective guards.
   (e)   All underground electrical wiring shall be encased in rigid conduit with eighteen inch cover. Any overhead wiring shall also meet the approval of the Commissioner of Building, in accordance with the National Electrical Code adopted in Chapter 1145.
   (f)   The earth station shall be bonded to an eight foot grounding rod.
   (g)   Guy lines if used shall be confined in a fenced area, with a minimum height of four feet.
   (h)   Plans shall meet all engineering practices.
(Ord. 1995-16. Passed 4-25-95.)