§ 50.15 ACCESS SYSTEMS FOR GATED COMMUNITIES AND COMMERCIAL PROPERTIES.
   50.15(A)   Access system requirement for fire rescue. All new and existing automatic entry gates to gated single-family, multi-family residential and commercial properties within the shall install and maintain at the 's expense, a , for fire rescue personnel, at each entry point into the community in compliance with Section F-108.9.3 of the including the Broward County Local Amendments. All existing automatic entry gates shall have the installed and fully operational no later than May 30, 2025.
   50.15(B)   Access system requirement for law enforcement, public works and authorized contractors. In addition to the for fire rescue as defined in § 50.15(A), all gated single-family, multi-family residential and commercial properties shall install and maintain at their expense, a remote control access system for the use of law enforcement, public works and authorized contractors working for the . This remote control access system shall comply with the following system specifications. The remote control system required by this § 50.15(B) is the "Linear Access Pro Receiver/Transmitter System," or any compatible system that meets the following specifications:
   50.15(B)(1)   Wireless based systems;
   50.15(B)(2)   Gate operators are capable of remote activation from a distance of up to 250 feet by the use of a radio-frequency, programmable transmitter;
   50.15(B)(3)   Transmitters are block-coded into the access Pro Receiver, or compatible receiver;
   50.15(B)(4)   Transmitters are capable of individual deletion from the system at any time;
   50.15(B)(5)   Outputs:
   50.15(B)(5)(a)   Relay: two form “C” relays, related at one amp @ two volts AC or DC;
   50.15(B)(5)(b)   LED display: three eight-segment displays to provide system activity and programming information;
   50.15(B)(5)(c)   LED indicators: front panel indicators are used in conjunction with LED display to provide transmitter and radio activity;
   50.15(B)(6)   Inputs:
   50.15(B)(6)(a)   RF: integral 318 MHz super regenerative receiver with -94 dBm sensitivity (nominal); receives MegaCode format transmitters;
   50.15(B)(6)(b)   Open request terminal: contact closure to ground activates access relay;
   50.15(B)(6)(c)   Open button: pressing activates access relays; also used to clear trouble codes from MGT;
   50.15(B)(6)(d)   Keypad: integral 15-key silicone rubber keypad for system programming and interrogation;
   50.15(B)(7)    Power: 12 to 24 volts AC or DC, 250 mA maximum.
   50.15(C)   Access for .   shall be authorized to gain access to any gated community within the to perform the duties of such in accordance with .
   50.15(D)   Maintenance. The maintenance and continuous working order of gate access systems defined in § 50.15(A) and § 50.15(B) shall be the responsibility of the / where they are installed.
(Ord. 2010-12, passed 10-4-2010; Am. Ord. 2024-07, passed 5-6-2024)