(a) All sanitary sewers installed and constructed in the Municipality shall be constructed of ASTM C-700 vitrified clay pipe which has full compression flexible joints and fittings, as hereinafter specified. However, in the case of sizes larger than twenty-four inches in diameter, such sewers may be constructed of concrete pipe with watertight joints approved by the Engineer.
(Ord. 1958-130. Passed 11-25-58.)
(b) All storm sewers installed and constructed in the Municipality shall be constructed of ASTM C-700 vitrified clay pipe and shall have full compression flexible joints and fittings, as hereinafter specified. However, in the case of sizes larger than eighteen inches in diameter, such sewers may be constructed of concrete pipe with watertight joints and classes approved by the Engineer. All storm sewers shall be installed in a trench separate from the sanitary sewer unless otherwise approved by the Council.
(Ord. 1966-13. Passed 3-8-66; Ord. 2006-022. Passed 3-7-06.)