§ 150.047 FIRE SAFETY.
   (A)   Bales of straw or other flammable materials that do not meet the requirements of division (B) below shall not be used for skirting or insulation of the manufactured home.
   (B)   Garages, carports, porches, awnings, sheds, skirtings and other similar appurtenances shall be constructed of material designed for exterior use that meets the flame spread rating of 200 or less in accordance with the American Society of Testing and Materials, Standard Method of Test for Surface Burning Characteristics of Building Materials (Standard E84).
   (C)   Manufactured home communities constructed after July 1, 1998 must be located in a fire protection district and provided with fire hydrants within 500 feet of any structure in the manufactured home community. As an alternative to fire hydrants, a holding pond or other source of water of 100,000 gallons or more accessible to the Fire Department may be used, if the Fire Department is capable of pumping from the body of water.
   (D)   Flammable liquids and gasoline-powered equipment other than motorized vehicles shall not be stored within five feet of a manufactured home, except when stored in a shed or garage.
   (E)   All intended means of egress shall not be obstructed.
(1975 Code, § 35-270) (Ord. 2023-7-19A, passed 7-19-2023)