The following development standards shall apply to lots located within the "R-3" District:
Minimum lot area | • Single-family detached dwelling - 7,500 square feet • Two family dwellings - 5,000 square feet per dwelling • All other non-residential uses - 43,560 square feet |
Maximum lot coverage | • 70% for all impervious surfaces for single-family detached dwelling uses • 80% for all impervious surfaces for all other uses |
Minimum lot frontage | • 50 feet |
Minimum front yard depth from the building line | • 25 feet • For infill development, if three or more dwellings are within 500 feet of the infill lot, then the average front yard setback shall be observed |
Minimum side yard setback from the building line | • Principal structure - 5 feet; 10 feet sum of side yard widths • Accessory structure - 5 feet |
Minimum rear yard setback from the building line | • Principal structure - 5 feet • Accessory structure - 5 feet |
Maximum building height | • Principal structures - 35 feet • Accessory structures - 15 feet |
Minimum floor area per family | • 800 square feet |