§ 17.06 APPROVAL.
   (A)   Modifications. Whenever there are practical difficulties involved in carrying out the provisions of this code, the Code Official shall have the authority to grant modifications for individual cases upon application of the owner or owner’s representative; provided, the Code Official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that the modification does not lessen health, life and fire safety requirements. The details of action granting modifications shall be recorded and entered in the Department files.
   (B)   Alternative materials, methods and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any method of construction not specifically prescribed by this code; provided that, any such alternative has been approved. An alternative material or method of construction shall be approved where the Code Official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.
   (C)   Required testing. Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods, the Code Official shall have the authority to require tests to be made as evidence of compliance at no expense to the jurisdiction.
      (1)   Test methods. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the Code Official shall be permitted to approve appropriate testing procedures performed by an approved agency.
      (2)   Reports. Reports of tests shall be retained by the Code Official for the period required for retention of public records.
   (D)   Used material and equipment. The use of used materials which meet the requirements of this code for new materials is permitted. Materials, equipment and devices shall not be reused unless the elements are in good repair or have been reconditioned and tested when necessary, placed in good and proper working condition and approved by the Code Official.
   (E)   Approved materials and equipment. Materials, equipment and devices approved by the Code Official shall be constructed and installed in accordance with the approval.
   (F)   Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.
(Adopted 10-11-2016)