§ 10-1-6 AMENDMENTS TO THE INTERNATIONAL PLUMBING CODE.
   The Town of Vail hereby adopts, by reference, all amendments to the International Plumbing Code, 2021 edition, as adopted by the State of Colorado and referred to as the “Colorado Plumbing Code”, in addition the following amendment:
   Section 101.1 Title: Section 101.1 is amended to read as follows:
101.1 Title. These regulations shall be known as the ‘Vail Plumbing Code’.”
   Section 103.1 Creation of Agency: Section 103.1 is amended to read as follows:
103.1 Creation of Agency. The Town’s Building Department is hereby created and the official in charge shall be known as the building official. The function of this agency shall be the implementation, administration, and enforcement of this code.”
   Section 115.4.: Section 115.4 is deleted.
   Section 305.4.1 Sewer depth: Section 305.4.1 is amended to read as follows:
305.4.1 Sewer depth. Per Eagle River Water and Sanitation District (ERWSD) standards, building sewers shall be installed not less than 54 inches (1372 mm) below grade.”
   Section 903.1 Roof extension: Section 903.1 is amended to read as follows:
903.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be terminated not less than 16 inches (406mm) above the roof.”
   Section 903.2 Frost closure: Section 903.2 is amended to read as follows:
903.2 Frost closure. Vent extensions through a roof or wall shall be not less than 3 inches (76 mm) in diameter. Any increase in size of the vent shall be made not less than 1 foot (305 mm) inside the thermal envelope of the building.”
(Ord. 8(2022) § 1)