§ 153.157 CONFLICT MANHOLES.
   Drain tile or storm sewers discovered to be at the same elevation as a wastewater sewer under construction may be handled as follows.
   (A)   A manhole will be constructed at the intersection of the pipes.
   (B)   A 16-foot minimum section of ductile-iron pipe will be laid through the manhole (centered on the manhole) and will be connected to and become a part of the wastewater sewer. Connection of dissimilar pipes shall be made with suitable couplings and concrete encasement.
   (C)   The drain tile or storm sewer shall be connected to the manhole but not laid through it.
(Ord. 97-7, passed 7-1-1997, § 5.16)